Integrated Control - Lennox EL296UH045XE36B Unit Information

El296uhe series
Hide thumbs Also See for EL296UH045XE36B:
Table of Contents

Advertisement

24VAC Indoor
Blower Terminals
Flame Sense
LED
S4 DIP Switches
Diagnostic Push
Button
3/16" QUICK CONNECT TERMINALS
FLAME SENSE SIGNAL
HI COOL 24VAC
HI HEAT 24VAC
LO COOL 24VAC
LO HEAT 24VAC
PAR
PAR
K
COMMON 24VAC
K
1/4" QUICK CONNECT TERMINALS
NEUTRALS = 120 VAC NEUTRAL
HUM = UNPOWERED NORMALLY OPEN (DRY) CONTACTS
LI = 120 VAC INPUT TO CONTROL
ACC = 120 VAC OUTPUT TO OPTIONAL ACCESSORY

INTEGRATED CONTROL

HUM
ACC
W2 = HEAT DEMAND FROM 2ND STAGE T/STAT
W1 = HEAT DEMAND FROM 1ST STAGE T/STAT
C = THERMOSTAT SIGNAL GROUND CONNECTED TO
TRANSFORMER GRD (TR) & CHASIS GROUND (GRD)
Y1 = THERMOSTAT 1ST STAGE COOL SIGNAL
Y2 = THERMOSTAT 2ND STAGE COOL SIGNAL
O = THERMOSTAT SIGNAL TO HEAT PUMP
DH = NOT USED
L = NOT USED
FIGURE 4
Page 9
Ignitor and Combustion
Air Inducer
Neutrals
On Board Links
THERMOSTAT CONNECTIONS (TB1)
DS = DEHUMIDIFICATION SIGNAL
R = CLASS 2 VOLTAGE TO THERMO­
STAT
G = MANUAL FAN FROM
T'STAT
REVERSING VALVE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents