Align the protrusion on the underside of the cover with the slots of the eyelets.
Then push cover firmly onto the housing to secure it.

SERVICING INSTRUCTIONS

CAUTION:   Before  doing  any  work  on  the  Brush  cutter,  always  switch  off  the  motor  
and  pull  the  plug  cap  off  the  spark  plug  (see  "Checking  the  spark  plug").
Always wear protective gloves.
CAUTION:   Never  remove  the  recoil  starter  for  yourself,  which  may  cause  an  
accident.It  should  be  asked  to  the  Authorized  Service  Agent.
To  ensure  a  long  service  life  and  to  avoid  any  damage  to  the  equipment,  the  following  servicing  operations  should  be  performed  at  regular  
intervals.
Daily checkup and maintenance
Before  operation,  check  the  machine  for  loose  screws  or  missing  parts.  Pay  particular  attention  to  the  tightness  of  the  cutter  blade  or  nylon  
cutting head.
Before  operation,  always  check  for  clogging  of  the  cooling  air  passage  and  the  cylinder  fins.
Clean them if necessary.
Perform the following work daily after use:
Clean the Brush cutter externally and inspect for damage.
Clean  the  air  filter.  When  working  under  extremely  dusty  conditions,  clean  the  filter  the  several  times  a  day.
Check the blade or the nylon cutting head for damage and make sure it is firmly mounted.
Check that there is sufficient difference between idling and engagement speed to ensure that the cutting tool is at a standstill while the
engine  is  idling  (if  necessary,  reduce  idling  speed).
If  under  idling  conditions  the  tool  should  still  continue  to  run,  consult  your  nearest  Authorized  Service  Agent.
Check  the  functioning  of  the  I-­O  switch,  the  lock-­off  lever,  the  control  lever,  and  the  look  button.
Cleaning of air cleaner
Unscrew screw (1).
Remove the air cleaner cover (3).
Take  out  the  sponge  element  (2),  wash  it  in  lukewarm  water  and  dry  it  completely.
After  cleaning,  put  back  the  air  cleaner  cover  (3)  and  fasten  it  with  screw  (1).
NOTE:   If  there  is  excessive  dust  or  dirt  adhering  to  the  air  cleaner,  clean  it  every  
day. A clogged air cleaner may make it difficult or impossible to start the
engine or increase the engine rotational speed.