Advanced Operation
Source Routing/Configuration
Figure 39
Quick Start Selection button at the bottom of the page. Manual configuration of Threshold, Attack, Release, and Depth of Cut can be adjusted in this page. These items are
defined as follows:
Threshold – Sets the level in dB below which the secondary input will be engaged.
Attack – Defined as the time it takes for the secondary source to engage. This can range from 0.1 seconds to 1.0 seconds
Release – Defined as the time it takes for the primary input to re-engage one the threshold level is exceeded.
Depth of Cut – Defined as the level in dB of the primary source is held at if the release time is not exceeded.
Analog Only: This is the audio input from the audio connector on the back panel of the amp. Choices for the Analog Audio input are Channel 1, Channel 2, or a sum of
Channels 1 and 2.