Diagram 7.21 - Battery Bracket, Front Retaining Bracket
Mounting
Nut
7.
Remove the nut fastens the front battery retaining bracket. Refer to Diagram 7.18. Carefully,
slide the battery out of the battery bracket.
8.
Remove the red and black wires from the replacement battery. Place a piece of electrical
tape over each of the battery terminals. Ensure that the side bracket is correctly in place in
the slots in the battery bracket and carefully slide the battery into the bracket.
9.
Replace the front retaining bracket and fasten it with its mounting nut.
10. Remove the electrical tape from the battery terminals and reconnect the battery wires as
follows: the red wire to the positive (+) battery terminal and the black wire to the negative (-)
terminal. Note: There is a red dot next to the positive terminal of the battery.
11. Set the lower PCA in its mounting position and fasten it with the screws removed in step 5.
12. Reconnect the lower PCA wiring as follows: power adapter cable to J4, generator cable to
J1, data cable to J2, lift cable to j3, load wires to terminals M1 and M2 (either wire may be
connected to either the M1 or M2 terminal).
13. Replace the rear cover. Check the operation of the EFX as described in Section Four.