Menu 5: Enter Zone Number
NOTES:
This menu starts Zone Programming, which lets you
program basic zone attributes. Enter the desired zone
number at this prompt, then press [∗]. The Zone
Programming page (menu 6) appears.
When all zones have been programmed, enter 00 to
advance to the Quit menu.
Zone Number
Programming Option
a. Zone Number
Menu 6: Zone Programming
NOTES:
Pressing [∗] at the Zone Number prompt displays the
Zone Programming page. To program additional zone
attributes, or to use any other menu mode of
programming, use standard control panel programming
mode (installer code + 800).
DISPLAY NOTE: Typical hardwired zone shown in the
example display. For wireless zones, the Resp / Config line is
replaced by the serial number entry line:
S/N Axxx – xxxx

Zone Programming

Programming Option
a. Zone Type
b. Send Report
c. Partition
d. Input Type
Entries
Control
Vista-20P and Vista-21iP:
Vista-15P:
Vista-10P:
† Zone Expander Zones; †† RF button zones; ††† Emergency zones
[∗ ∗ ∗ ∗ ] = continue programming the selected zone
00 = go to Quit menu
Loop
x
Entries
|
Enter Zone No
Wired Zone
01-08; 09-48
†††
95, 96, 99
01-06; 09-24
†††
95, 96, 99
01-06
†††
95, 96, 99
Zone Programming
Type: 09
Send Report:
Input Type:
Resp: 350mS
Library
Disp :
xxxxxxxxxxxxxxxx
Field
Enter the 2-digit Zone Type from the table below.
00 = Not used
01 = Entry/exit #1
02 = Entry/exit #2
03 = Perimeter
∗56
04 = Int. Follower
05 = Day/Night
06 = 24-Hr Silent
To disable the current zone, enter 00.
Press [∗] to advance.
0 = No – do not send report
∗56
1 = Yes – send report
1 = parition 1
2 = partition 2
∗56
3 = partitions 1 & 2
Applies only to partitioned controls.
Press [∗] to advance.
For built-in hardwired zones, the input type
automatically displays "Hardwired." For wireless
and auxiliary wired zones, select the input type:
2 = Aux (Aux wired zone; ex. 4219, 4229)
∗56
3 = RF. Trans. (supervised RF transmitter)
4 = Unsupv. RF (unsupervised RF transmitter)
5 = RF Button (Unsupervised Button RF)
Press [∗] to advance.
– 4 –
Field
RF Zones
††
09-48; 49-64
††
09-34; 49-56
∗56
09-24
††
49-56
#01
Fire
Y
Part
1
Hardwired
Config: EOL
000
000
000
Notes
07 = 24-Hr Audible
20 = Arm–STAY*
08 = 24-Hr Aux
21 = Arm–AWAY*
09 = Fire
22 = Disarm*
23 = No Alarm Resp
10 = Interior w/Delay
12 = Monitor Zone
24 = Silent Burglary
14 = Carbon Monoxide 77 = Keyswitch
16 = Fire w/Verify
81 = AAV Mon. Zone
01