Why The Chimney Should Penetrate The Highest Heated Space - Drolet Myriad II DB03051 Installation And Operation Manual

Hide thumbs Also See for Myriad II DB03051:
Table of Contents

Advertisement

Myriad II Installation and Operation Manual
Good System Design
Inferior System Design
Inside chimneys are preferred because even
Outside chimneys are a problem
when no fire is burning, there is normally
because when no fire burns they will go
upward flow in the system.
into cold backdraft if the stove is
installed low in the house.

8.4.2 Why the chimney should penetrate the highest heated space

When it is cold outside, the warm air in the house is buoyant so it tends to rise. This
tendency of warm air to rise creates a slight pressure difference in the house. Called 'stack
effect', it produces a slightly negative pressure low in the house (relative to outside) and a
slightly positive pressure zone high in the house. If there is no fire burning in a heater
connected to a chimney that is shorter than the warm space inside the house, the slight
negative pressure low in the house will compete against the desired upward flow in the
chimney.
There are two reasons why the
chimney in the house at right will
cold backdraft when it is cold
outside and there is no fire
burning in the stove. First, the
chimney runs up the outside of the
house, so the air in it is colder and
denser than the warm air in the
house. And second, the chimney
is shorter than the heated space
of
the
house,
meaning
the
negative pressure low in the
house will pull outside air down
the chimney, through the stove
and into the room. Even the finest
stove will not work well when
connected to this chimney.
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Legend ii db03071Austral ii db03031Baltic ii db03041

Table of Contents