Download Print this page

Front Panel - Bryston 2.5B3 Owner's Manual

Advertisement

Front Panel

1. Power/Standby Switch:
The front panel features a push-on/push-off
type latching power switch used to apply or
remove A/C line power to the SoftStart circuitry.
Note that the rear circuit breaker must be on for
the amplifier to power-up.
2. LED Indicator:
Each amplifier channel has a front panel LED
indicator to monitor the following conditions:
Unlit
Amplifier not powered on (OFF
MODE)
Red
Channel is muted during power up
Green
Channel operation is normal
Flashing
Channel is clipping. Reduce input
Red
level!
Orange
Thermal protection mode
POWER UP SEQUENCE
After pushing the power switch, each channel
LED will turn from unlit to red (mute). When the
power supplies have stabilized, the channel will
come out of mute and the LED will change to
green (normal operation).
UNLIT LED
(No power)
The amplifier channel LED when unlit indicates
no A/C mains power is present at the channel
power transformer. This usually indicates
that the amplifier probably needs only to be
powered on.
2.5B
Amplifier
3
3
1
2
CLIPPING
Clipping occurs when the channel output level
no longer can follow the level increase at the
input (over driven input condition). When a
channel is driven into clipping, the channel
LED will change from green to red then back to
green when the level is reduced. Momentary
clipping can be tolerated, however it indicates
that maximum undistorted power has been
surpassed and potential speaker damage
may result if overload conditions persist. Any
amplifier that is constantly operated into
clipping indicates a more powerful amplifier is
needed for that application.
THERMAL SHUTDOWN
Each channel has thermal shutdown circuitry
to prevent damage due to overheating. Should
thermal shutdown occur, the channel will mute,
and the channel LED will turn orange. When
the channel has cooled to a safe operating
condition, the channel will return to normal
operation. Persistent thermal shutdown
indicates steps need to be taken to increase
airflow across the channel or channels heat
sink. See "Ventilation" on page 4.
In some markets the LED indicators, which are
normally red/green, may be red/blue instead.
When red/blue LEDs are supplied green is
replaced with blue and orange is replaced with
magenta in the above descriptions.
(flashing red)
(orange)
7

Advertisement

loading