[5-1 Dipswitch Functions and Factory Settings ]
(2) Additional dipswitch settings at time of shipment
Switch
SW4
1-10
SW6-10:
1:ON, 0:OFF
OFF
No.769
1000000011
No.832
0000001011
No.848
0000101011
No.896
0000000111
No.897
1000000111
No.900
0010000111
No.912
0000100111
No.913
1000100111
No.915
1100100111
No.916
0010100111
SW4
1-10
No.918
0110100111
[0:OFF,
1:ON]
(Note 1)
No.921
1001100111
SW6-10:ON
No.922
0101100111
No.932
0010010111
No.933
1010010111
No.934
0110010111
No.964
0010001111
No.972
0011001111
No.982
0110101111
No.988
0011101111
HWE14040
Function according to switch setting
Function
OFF (LED3 Unlit)
Refer to the following page(s). [9 LED Status
Self-diagnosis/operation
Indicators on the Outdoor Unit Circuit
monitor
Board](page 289)
Test run mode: ON/OFF
Stops all ICs
Cumulative compressor
Retained
operation time deletion
Continuous heating cycle
Disabled
function
OC
Retained (IC/OC)
Clearance of error
history
OS
Retained (OS)
High sensible heat opera-
Depends on the combined setting with No.
tion setting
900 (Note 4)
High sensible heat opera-
Depends on the combined setting with No.
tion setting
897 (Note 4)
Pump down function
Normal control
Forced defrost (Note 3)
Normal control
P200 - P300:
Defrost start temperature
-13°C [9°F]
(Note 3)
P350 - P450:
-11°C [12°F]
P200, P250:
Defrost end temperature
10°C [50°F]
(Note 3)
P300 - P450:
7°C [45°F]
Changes the defrost timer
50 minutes
setting (Note 3)
Temperature unit display
°C
Refrigerant amount adjust-
Normal control
ment
Heating backup
Disabled
Effective only when
TH7 ≤ 5 is true or the
Snow sensor setting
snow sensor contact
input is on.
Continuous fan op-
Snow sensor setting
eration (FAN=50%)
Target evaporation tem-
Depends on the setting combination with No.
perature setting
982 (Note 5)
Automatic cooling/heating
mode (IC with the smallest
Normal control
address)
Target evaporation tem-
Depends on the setting combination with No.
perature setting
964 (Note 5)
Refrigerant recovery/Evac-
uation (two-way valve/
Disabled
LEV1 open)
- 86 -
Switch setting timing
ON (LED3 Lit)
Anytime after power on
Sends a test-run sig-
Anytime after power on
nal to all IC
Any time after being energized (When
Cleared
changed from OFF to ON)
After being energized and while the com-
Enabled
pressor is stopped
Deleted (IC/OC)
Anytime after power on (OFF→ON)
Deleted (OS)
After being energized and while the com-
pressor is stopped
After being energized and while the com-
pressor is stopped
Pump down opera-
After being energized and while the com-
tion
pressor is stopped
10 minutes after the completion of de-
Forced defrost starts
frost operation (OFF→ON) or 10 minutes
after compressor start-up (OFF→ON)
-8°C [18°F]
Anytime after power on
5°C [41°F]
Anytime after power on
90 minutes
Anytime after power on (OFF→ON)
°F
Anytime after power on
When the compressor is in operation (ex-
Refrigerant amount
cept during initial startup/becomes inef-
adjust mode
fective 90 minutes after compressor
started up.)
Enabled
Anytime after power on
Effective when TH7
Anytime after power on
≤ 5 is true
Intermittent fan op-
eration (The fan op-
erates in the cycle of
being in operation at
100% capacity for 5
Anytime after power on
minutes and then
stops and remains
stopped for 30 min-
utes.)
Anytime after power on
Automatic cooling/
Before power on (After configuring the
heating mode
setting, perform a power reset.)
Anytime after power on
After being energized and when units are
Enabled
stopped
Units that
require
switch
setting
(Note 2)
C
A
C
B
C
A
A
A
D
B
B
B
C
A
A
C
C
A
A
A
C