York D1SV300 Installation Instructions Manual page 8

Sunline series single package air conditioners
Table of Contents

Advertisement

530.25-N2
TABLE 3 – (A) ELECTRICAL DATA – UNITS WITHOUT EXHAUST AIR FANS'
300
360
480
~
)&w
w . .
17
28
46
58
17
28
46
58
17
28
46
58
M
[
1
10
I
0000
I
225
10
705
-.
10
I
44++
'/2 (6) 2.Oea.
105
110
125
/2 (6)
2.Oea.
~~
100
110
'/2 (6) 3.4ea.
~~~
300
----
0000
208 25 (1)
101
470
0.84
/. 1/.? L>
103
200 10
32
200 314(3) 4.2
ea.
175
20
230
25 (1)
92
470
0.76
71/2
22
150
17
230 10
28
230 3/4 (3) 4.2
ea.
160
20U
Uu
Z.su
460
25 (1)
46
235
0.76
460 7.1/2 11
10
14
460 3/4 (3) 2.4ea.
80
90
4
360
575
25 (1)
37
200
0.76
575 7-1/2
9
10
11
4606 3/4 (3) 2.4ea.
65
80
6
365
208
30 (1)
126
565
0.90
10
32
210
25
200 15
48
200 1/2 (6) 3.4ea.
230
30
230
30 (1)
122
565
0.81
10
28
205
230 15
42
230 1/2 (6) 34
ea.
215
25I
460
30 (1)
61
283
0.81
460 /:
;;
460 1
"
-
'-
-
575
30 (1)
49
230
0,81
575 ~:
;;
460' 1
208
20 (2)
15
48
83
ea. 428ea. 0.90ea.
208 F.
59
200 1
230
20 (2)
80
ea. 428ea. 0.81ea.
230 ;;
;:
230 1/2 (6)13.4ea.I ~~~ I 30
460
20 (2)
40
ea.
214
ea.
0.81
ea.
15
21
460
20
27
460 1
575
20 (2)
33ea. 160ea. 0.81ea.
575 ;;
;;
4606 1
1
1 , ," 1
1
I
.""
4
3
250
300
1=
250
235
2
400
385
405
450
205
220
~9n
" Cluantlty Ilsted In ( )
1 Refer to the followlng
table for electrical data of unit w!th exhaust a! r fans
~
4 Based on three 75'C, Insulated copper conductors in steel condu!t
2 Rated at a 45"ET and a 130"CT
Based on a 3?/. voltage drop
3 Dual element, time delay type
6 A 575 to 460 VOIt transformer IS prcwded for these motors
TABLE
3 –
(B) ELECTRICAL DATA – UN ITS WITH EXHAUST Al R FANS]
360
480
$wq#y
m
%&W
AR t%
Wit
Max.
Min.
I
Max.
Metm{lwlas$l
Amp8-
Fw
W@
Wim
1"
c~ty,
Skt$?
Size,3
Lewjth,'
Vf?tb
H?{*)
FLA
Amps
Asnp$
JWWMcrd I%@
f
17
7-1/2
200
3/4 (2)
4.2 ea.
175
200
00
185
10
180
225
000
215
28
7-1/2
230
3/4 (2)
4.2 ea.
160
200
00
230
10
165
220
46
7-1/2
10
460
3/4 (2)
2.4 ea.
85
100
4
335
58
7-1/2
10
460s
3/4 (2)
2.4 ea.
70
80
4
510
17
10
200
3/4 (2)
4.2 ea.
220
250
0000
215
15
235
300
250
220
28
10
230
314(2)
4.2 ea.
210
250
0000
245
15
225
300
225
46
10
460
3/4 (2)
2.4ea.
110
125
2
385
15
115
150
365
58
10
4605
3/4 (2)
2.4ea.
90
110
3
475
15
100
425
17
270
300
;;
200
3/4 (3)
4.2
ea.
300
220
280
350
210
28
15
230
314(3)
4.2 ea.
255
300
250
220
20
270
300
230
46
15
460
3/4 (3)
2.4ea.
135
150
0
450
20
140
435
58
15
4605
3/4 (3)
2.4 ea.
115
125
2
460
20
120
1
525
-
-
" Cluantlty Ilsted In ( ).
~ Based on three 75 'C, lnsu Iated copper conductors n steel corId II
I t
'
Refer to table above for electrical data on compressors and fan motors
Based on a 3?4 voltage drop
2 Dual element, time delay type
5 A 575 to 460 VOIt transformer IS provided for these motors
8
Central Environmental
Systems

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D1sv360D2sv300D2sv360D2sv480D1sv480

Table of Contents