Ports
R, S, T
Power supply ports
U, V, W
Compressor ports
E
Grounded port
N
Neutral wire port
L1, L2
CN102
Current transducer port
CN211,
Fan motor port
CN212
CN205
Water pump port
CN206
Electric heater port
CN207
Solenoid valve port
CN208
Solenoid valve port
CN209
Four-way valve port
CN210
Oxygen generator port
CN302
Testing board port
CN303
Testing software port
CN304
Communication port
CN307,
Fan motor port for dispersing
CN308
heat
CN310
EEV port
CN311
Radiator temp. sensor port
Mid-condenser temp. sensor
CN312
port
CN313
Defrosting temp. sensor port
CN314
Ambient temp. sensor port
CN315
Suction temp. sensor port
Discharging
CN316
port
CN317
Low pressure switch port
CN318
High pressure switch port
Commercial Air Conditioner
Ports name
temp.
sensor
- 71 -
Wiring method
To power of 3 PH, 380V, 50Hz
To motor (pay attention to phase sequence)
Grounding (less than 10Ω;more thanφ1.6mm)
It is connected to neutral wire
Shorted now
To current transducer
To fan motor
To water pump (be spare)
To electrical heater
To solenoid valve
To solenoid valve
To four-way valve
To oxygen generator (optional)
To testing board. Used to modify, check data for
after sale personnel.
To testing computer. Used to modify, check data
for after sale personnel.
To C1, C2 of communication block
To fan motor for dispersing heat (be spare)
To outdoor electronic expansion valve
To radiator temp. sensor (blank temporarily)
To mid-condenser temp. sensor
To defrosting temp. sensor
To ambient temp. sensor
To compressor suction temp. sensor
To discharging temp. sensor
To low pressure switch port
To high pressure switch