Connect The Cable To The Outdoor Unit - Panasonic CS-W12CTP Service Manual

Room air conditioner
Hide thumbs Also See for CS-W12CTP:
Table of Contents

Advertisement

9.3.6.

CONNECT THE CABLE TO THE OUTDOOR UNIT

1. Remove the control board cover from the unit by loosening the screw.
2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 x 1.5mm
2
x 1.5mm
(W12CT) or 3 x 2.5mm
cord.
3. Secure the cable onto the control board with the holder (clamper).
4. Attach the control board cover back to the original position with the screw.
9.3.7.
PIPE FORMINGS, INSULATION AND FINISHING
1. If you may connect an additional drain hose, the end of the
drain-outlet should keep distance from the ground.
CAUTION
(Do not dip it into water, and fix it on the wall to avoid
swinging in the wind.)
In case of the Outdoor unit is installed
below position of the indoor unit.
2. Tape the Pipings, drain hose and Connecting Cable from
down to up.
3. From the pipings gathered by taping along the exterior wall
and fix it onto the wall by saddle or equivalent.
(Refer to the right side diagram)
DISPOSAL OF OUTDOOR UNIT DRAIN WATER
• • • • If a drain elbow is used, the unit should be placed on a
stand which is taller than 3 cm.
• • • • If the unit is used in an area where temperature falls below
0°C for 2 or 3 days in succession, it is recommended not to
use a drain elbow, for the drain water freezes and the fan
will not rotate.
2
(V18/24CT) or 5 x 2.5mm
In case of the Outdoor unit is installed upper position of the indoor unit.
CS-W12CTP CU-W12CTP5 / CS-W18CTP CU-W18CTP5 / CS-W24CTP CU-W24CTP5
2
(W18/24CT) flexie cord, type designation 2451EC57 or heavier
1. Tape the Pipings, and Connecting cable from down to up.
2. From the pipings gathered by taping along the exterior wall
and the trap is required to prevent water from entering the
room.
3. Fix the pipings onto the wall by saddle or equivalent.
(Refer to the left side diagram)
53
2
(V12CT) or 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-w18ctpCu-w18ctp5Cu-w12ctp5Cs-w24ctpCu-w24ctp5

Table of Contents