7.2.

Soft Dry Mode Operation

• • • • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
• • • • During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
• • • • The operation will be switched on and off for up to 10 minutes "ON" and 6 minutes "OFF". Once Soft Dry operation is turned
off, it stops for 6 minutes.
Time Delay Safety Control
• • • • Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Anti-Freezing Control
• • • • Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
Compressor Reverse Rotation Protection Control
• • • • Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
Compressor Protection Control
• • • • Same as Compressor Protection Control for Cooling Mode Operation.
Anti-Dew Formation Control
• • • • Same as Anti-Dew Formation Control for Cooling Mode operation.
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
• • • • Fan speed rotates at Lo- speed.
CS-W12CTP CU-W12CTP5 / CS-W18CTP CU-W18CTP5 / CS-W24CTP CU-W24CTP5