Nikon COOLPIX S550 Repair Manual page 66

Hide thumbs Also See for COOLPIX S550:
Table of Contents

Advertisement

Caution:
 
The luminance of pattern box is measured by [BM-3000], but sometimes the measurement result of each [BM-3000]
varies.
Therefore, to keep the same luminance without such variation, the method by using the inspection report which is
supplied with BM-300 is as follows.
The inspection report is in Japanese only. Refer to data only at overseas service facilities.
Procedure
① Find the corresponding value by crossing K=1.3 and EV13 in the accessory inspection report, and calculate
by putting the corresponding value into the below formula.
e.g.
Coefficient
1365.2cd/ ㎡
 168.89× 
    256 
Coefficient
The calculated result corresponds to " EV12.4 " of
the inspection report.
- A39 ・ S550 -
INC
VMA21024-R.3750.A
900cd/ ㎡

Advertisement