10-3. Outdoor Unit

RAS-10SAH-ES
No.
Part name
Common
procedure
Capacitor for
compressor
ƒ
Capacitor for fan
motor
RAS-13SAH-ES
No.
Part name
Common
procedure
Capacitor for
compressor
ƒ
Capacitor for fan
motor
Procedure
1) Stop the operation of air-conditioner, and disconnect
the power cord from the AC supply.
2) Remove E-parts cover. (1- ST1T ø4 x 10 )
3) Remove the cord clamp (2- ST2T ø4 x 12 ) and
remove the connecting cable.
4) Remove the front cabinet.
(7- ST1T ø4 x 10
with nylon washer)
• Pull the front lower portion toward you, and remove
it pulling out upward.
1) Remove the fixing screw securing the capacitor
band. (1- ST2T ø4 x 8 )
2) Remove the cable connected to the terminal.
1) Remove the fixing screw. (1- ST2T ø4 x 8 )
2) Remove the cable connected to the terminal.
Procedure
1) Stop the operation of air-conditioner, and disconnect
the power cord from the AC supply.
2) Remove E-parts cover. (2- ST1T ø4 x 10 )
3) Remove the cord clamp (2- ST2T ø4 x 12 ) and
remove the connecting cable.
4) Remove the front cabinet.
(7- ST1T ø4 x 10
with nylon washer)
• Pull the front lower portion toward you, and remove
it pulling out upward.
1) Perform the process
2) Remove the fixing screw securing the capacitor
band. (1- ST2T ø4 x 8 )
3) Remove the cable connected to the terminal.
1) Perform the process
2) Remove the fixing screw. (1- ST2T ø4 x 8 )
3) Remove the cable connected to the terminal.
above.
above.
– 58 –
Remarks
Refer to [Electrical parts list and
location] in page 66/67.
Same as above.
Remarks
1-ST2T
1-ST2T
φ4 x 8
φ4 x 8
1-ST2T
φ4 x 10

Hide quick links: