Toshiba RAS-10SKH-ES Service Manual page 12

Split wall type
Table of Contents

Advertisement

RAS-13SKH-ES/RAS-13SAH-ES
Cooling
0,49m
Heating
(Connecting pipe)
ø9,52
O.D.:9,52mm
Packed valve
Heating
Cooling
4-way valve
Heating Cooling Compressor
Cooling
Heating
50Hz
Standard
Heating
High temperature*1
Low temperature
Standard
Cooling
High temperature
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
1
• During heating overload, the high temperature limit control operation is included.
*
P
(ø9,52)
Gas container connection (Reinstall etc.)
Muffler
PA160X2T-4FM
Condenser
Propeller fan
Outdoor unit
Standard pressure
P
(MPaG)
RAS-13SKH-ES
2,7
3,2 ~ 3,6
2,0
0,9
1,0
0,6
T1
Indoor unit
Heat exchanger
Cross flow fan
Dryer
Capillary tube
ø1,2x1200
Mark (
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
RAS-13SKH-ES
43,0
52,0 ~ 57,0
30,0
11,0
14,0
2,0
– 12 –
(Note)
Maximum pipe length is 15m
Maximum pipe head is 6m
Packed valve
(ø6,35)
Capillary tube
ø1,5x500
Refrigerant
R-410A 0,80kg
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(indoor)
Indoor
High
20/–
Low
27/–
High
20/–
High
27/19
High
32/23
Low
21/15
0,39m
(Connecting pipe)
ø6,35
O.D.:6,35mm
(°C)
Outdoor
7/6
21/15
–10/–10
35/24
43/26
21/15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sras-13skh-esRas-10sah-eRas-13sah-es