Steam connection

The steam supply to the machine should be fit-
ted with manual shut-off valves and filters to faci-
litate installation and servicing.
The connection hose must be of type ISO/1307-
1983 or equivalent. Connection size at filter:
DN 15 (BSP 1/2").
Steam pressure required:
• minimum: 50 kPa (0.5 kp/cm
• maximum: 800 kPa (8 kp/cm
• Remove the cover (A).
32
• Mount the articulated nipple to the steam
33
valve.
• Mount the steam valve on the machine.
34
• Mount nipple, strainer and elbow. Note the
35
direction of the strainer. Mount steam hose to
the elbow.
Check that there are no sharp angles or bends
on the connected steam hose.
• Mount the hose with wires between steam
36
valve and machine.
Connect wires in the steam valve.
Connect ground cable to the terminal ground
connection.
Mount the cable connector on X46 on distri-
bution card.