Section 2 Operation; Operating Sequence Description; Off Condition; Cooking Condition - Electrolux EI24MO45IBA Technical & Service Manual

Table of Contents

Advertisement

Operating Sequence Description

The following is a description of component functions
during oven operation.

OFF CONDITION

Closing the door activates the door sensing switch and
secondary interlock switch. (In this condition, the monitor
switch contacts are opened.)
When oven is plugged in, 120 volts A.C. is supplied to the
control unit. (See Figure 2-1).
1. The display will show "ENJOY YOUR OVEN, PRESS
CLEAR AND PRESS CLOCK".
To set any program or set the clock, you must first
touch the STOP/CLEAR pad. The display will clear,
and " : " appears.

COOKING CONDITION

Program desired cooking time by touching the NUMBER
pads. Program the power level by touching the POWER
LEVEL pad and then a Number pad.
When the START pad is touched, the following operations
occur:
1. The contacts of relays are closed and components
connected to the relays are turned on as follows.
(For details, refer to Figure 2-2)
RELAY CONNECTED COMPONENTS
RY-1
Oven Lamp / Turntable Motor / Fan Motor
RY-2
Power Transformer
2. 120 volts AC is supplied to the primary winding of
the power transformer and is converted to about
3.3 volts AC output on the filament winding, and
approximately 2370 volts AC on the high voltage
winding.
3. The filament winding voltage heats the magnetron
filament and the H.V. winding voltage is sent to a
voltage doubler circuit.
4. The microwave energy produced by the magnetron
is channeled through the waveguide into the cavity
feedbox, and then into the cavity where the food
is placed to be cooked.
5. Upon completion of the cooking time, the power
transformer, oven lamp, etc. are turned off, and the
generation of microwave energy is stopped. The
oven will revert to the OFF condition.
6. When the door is opened during a cook cycle, the
monitor switch, door sensing switch, third door
switch, primary switch relay (RY1) and secondary
interlock relay are activated with the following results.
The circuits to the turntable motor, the cooling fan
motor, and the high voltage components are de-
energized, the oven lamp remains on, and the digital
read-out displays the time still remaining in the cook
cycle when the door was opened.
7. The monitor switch electrically monitors the operation
of the primary and third door switch and is mechani-
cally associated with the door so that it will function in
the following sequence.
(1) When the door opens from the closed position,
the secondary interlock relay (RY2) secondary
switch open their contacts. And contacts of the
relay (RY1) remains closed. Then the monitor
switch contacts close.
(2) When the door is closed from the open position,
the monitor switch contacts open first. Then the
contacts of the primary switch, third door switch
and door sensing switch close. and the contacts
of the relay (RY1) open.
If the primary interlock switch and secondary interlock
relay (RY2) fail with the contacts closed when the door is
opened, the closing of the monitor switch contacts will
form a short circuit through the C/T fuse, primary interlock
switch, relay (RY1) and secondary interlock relay (RY2),
causing the C/T fuse to blow.
2-1