Clearance To Combustibles - Carrier 58MCB120 Product Data

Table of Contents

Advertisement

Clearance to combustibles

This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size Furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m).
An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
This furnace is for indoor installation in a building constructed on site. This furnace may be installed in a manufactured (mobile) home when stated on rating plate and using factory
authorized kit.
This furnace may be installed on combustible flooring in alcove or closet at minimum clearance from combustible material.
This appliance requires a special venting system. Refer to the installation instructions for parts list and method of installation. This furnace is for use with schedule-40 PVC, PVC-DWV,
CPVC, or ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be installed is maximum 24 inches
(600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials).
Cette fournaise à air pulsé est équipée pour utilisation avec gaz naturel et altitudes comprises entre 0 - 3,050m
(0-10,000 pi), excepté queles fournaises de 140 taille sont pour altitudes comprises entre 0 - 2,135m (0 - 7,000 pi).
Utiliser une trousse de conversion, fournie par le fabricant, pour passer au gaz propane ou pour certaines installations au gaz naturel.
Cette fournaise à air pulsé est pour installation à l´intérieur dans un bâtiment construit sur place. Cette fournaise à air pulsé peut être installée dans une maison préfabriquée
(maison mobile) si prescrit par la plaque signalétique et si l´on utilise une trousse specifiée par le fabricant.
Cette fournaise peut être installée sur un plancher combustible dans un enfoncement ou un placard en observant les dégagements minimums avec les matériaux combustibles.
Cet appareil nécessite un système d´évacuation spécial. La méthode d´installation et la liste des pièces nécessaires figurent dans les instructions d´installation.Cette fournaise doit
s´utiliser avec la tuyauterie des nomenclatures 40 PVC, PVC-DWV, CPVC, ou ABS-DWV et elle ne peut pas être ventilée conjointment avec d´autres appareils à gaz. Épaisseur de la
construction au travers de laquelle il est possible de faire passer les tuyaux d´aération (admission/évacuation): 24 po (600 mm) maximum, 3/4 po (19 mm) minimum (y compris la toiture).
For upflow and downflow applications, furnace must be installed level, or pitched within 1/2"
of level. For a horizontal application, the furnace must be pitched minimum 1/4" to
maximum of 1/2" forward for proper drainage. See Installation Manual for IMPORTANT unit
support details on horizontal applications.
Pour des applications de flux ascendant et descendant, la fournaise doit être installée de
niveau ou inclinée à pas plus de 1/2" du niveau. Pour une application horizontale, la
fournaise doit être inclinée entre minimum 1/4" et maximum 1/2" du niveau pour le drainage
approprié. En cas d'installation en position horizontale, consulter les renseignements
IMPORTANTS sur le support dans le manuel d'installation.
MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION
ALL POSITIONS:
*
Minimum front clearance for service 30 inches (762mm).
††
140 size furnaces require 1 inch back clearance to combustible materials.
DOWNFLOW POSITIONS:
For installation on combustible floors only when installed on special base No. KGASB0201ALL, Coil
Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.
HORIZONTAL POSITIONS:
Line contact is permissible only between lines formed by intersections of top and two sides of furnace
jacket, and building joists, studs, or framing.
§
Clearance shown is for air inlet and air outlet ends.
120 and 140 size furnaces require 1 inch bottom clearance to combustible materials.
Ø
DÉGAGEMENT MINIMUM EN POUCES AVEC ÉLÉMENTS DE CONSTRUCTION COMBUSTIBLES
POUR TOUS LES POSITIONS :
*
Dégagement avant minimum de 762mm (30 po) pour l´entretien.
††
Pour les fournaises de 140 taille, 1 po (25mm) dégagement des matériaux combustibles est requis
au-arriere.
POUR LA POSITION COURANT DESCENDANT:
Pour l´installation sur le plancher combustible seulement quand on utilise la base spéciale, pièce
n° KGASB0201ALL, l´ensemble serpentin, pièce n° CD5 ou CK5, ou le carter de serpentin, pièce
n° KCAKC.
POUR LA POSITION HORIZONTALE:
Le contact n´est permis qúentre les lignes formées par les intersections du dessus et des deuxcôtés de la
chemise de la fournaise, et des solives, des montants ou de la charpente du bátiment.
§
La distance indiquée concerne l´extrémité du tuyau d´arrivée d´air et l´extrémité du tuyau de sortie d´air.
Pour les fournaises de 120 et 140 taille, 1 po (25mm) dégagement des matériaux combustibles est requis
Ø
au-dessous.
10
INSTALLATION
LEVEL (0")
TO
1/2" MAX
FRONT
UPFLOW OR
DOWNFLOW
324999-201 REV. D (LIT TOP)
MIN 1/4"
TO
1/2" MAX
FRONT
HORIZONTAL
This furnace is approved for UPFLOW, DOWNFLOW and
HORIZONTAL installations.
Cette fournaise est approuvée pour l´installation HORIZONTALE
et la circulation d´air VERS LE HAUT et VERS LE BAS.
1"
Clearance arrows
Les fléches de dégagement
ne change pas avec
do not change with
furnace orientation.
générateur d´air chaud.
††
0"
B
A
A
R
C K
R I
E
R
E
L È
F
R O
A V
N
A
T
0"
N T
3"
§
0"
Clearance in inches
Ø
Dégagement (po).
d´évent avec combustibles.
l´orientation de la
§
0"
S
E
R V
N T
I
R
C
E
E
*
T
I
E
30
N
MIN
Vent clearance to
combustibles 0".
0 (po) Dégagement