Viessmann Vitodens 200-W B2HA 100 Technical Data Manual page 14

Hide thumbs Also See for Vitodens 200-W B2HA 100:
Table of Contents

Advertisement

Low-Loss Header Information
Low-Loss Header Application
Sizing of Low-Loss Header in a Residential/Commercial Single-Boiler Application
Boiler
No. of
Boiler
Model
Boilers
Max.
Flow
Rate
B2HA
1
38
150
(8600)
*1 For system t < 20° F use low-loss header sizes for t 20° F.
*2 Low-Loss temperature sensor - optional equipment for use in single-boiler applications.
Sizing of Low-Loss Header in a Commercial Multiple-Boiler Application
Boiler
No. of
Boiler
Model
Boilers
Max.
Flow
Rate
B2HA
2
38
150
(8600)
B2HA
3
38
150
(8600)
B2HA
4
38
150
(8600)
B2HA
5
38
150
(8600)
B2HA
6
38
150
(8600)
B2HA
7
38
150
(8600)
B2HA
8
38
150
(8600)
Note: for multiple boiler applications when using the Vitodens 200-W, B2HA boilers, refer to the multiple boiler
low-loss distribution manifold installation instructions.
*1 For system t < 20° F use low-loss header sizes for t 20° F.
*2 Low-Loss sensor - standard equipment of the cascade control Vitotronic 300-K MW2B:
for use in multiple boiler applications.
14
(continued)
Total
Typical System Flow Rates
Flow
Rate
*1
t
38
System Flow
(8600)
Rate
LLH Required
LLH Model
Total
Typical System Flow Rates
Flow
Rate
t
*1
76
System Flow
(17200)
Rate
LLH Required
LLH Model
114
System Flow
(25800)
Rate
LLH Required
LLH Model
152
System Flow
(34400)
Rate
LLH Required
LLH Model
190
System Flow
(43000)
Rate
LLH Required
LLH Model
228
System Flow
(51600)
Rate
LLH Required
LLH Model
266
System Flow
(60200)
Rate
LLH Required
LLH Model
304
System Flow
(68800)
Rate
LLH Required
LLH Model
Vitodens 200-W B2HA 100 to 150 Technical Data
°F
20
25
(°C)
(11)
(14)
GPM
49.5
39.6
(L/h)
(11243)
(8994)
Yes
Optional
200/120
160/80
°F
20
25
(°C)
(11)
(14)
GPM
99
79
(L/h)
(22487)
(17990)
Yes
Yes
250/150
200/120
GPM
149
119
(L/h)
(33731)
(26985)
Yes
Yes
300/200
300/200
GPM
198
158
(L/h)
(44974)
(35979)
Yes
Yes
400/200
300/200
GPM
247.5
198
(L/h)
(56213)
(44971)
Yes
Yes
400/200
400/200
GPM
297
237.6
(L/h)
(67461)
(53969)
Yes
Yes
450/250
400/200
GPM
346.5
277
(L/h)
(78705)
(62964)
Yes
Yes
450/250
450/250
GPM
396
317
(L/h)
(89949)
(71959)
Yes
Yes
500/300
450/250
30
35
(17)
(19.5)
33
28
(7495)
(6424)
(5631)
Optional
Optional
Optional
120/80
120/80
120/80
30
35
(17)
(19.5)
66
57
(14991)
(12850)
(11244)
Yes
Yes
200/120
200/120
200/120
99
85
(22487)
(19275)
(16865)
Yes
Yes
250/150
250/150
200/120
132
113
(29983)
(25700)
(22487)
Yes
Yes
300/200
250/150
250/150
165
141.4
(37476)
(32122)
(28107)
Yes
Yes
300/200
300/200
300/200
198
170
148.5
(44974)
(38549)
(33731)
Yes
Yes
400/200
300/200
300/200
231
198
(52470)
(44974)
(39352)
Yes
Yes
400/200
400/200
300/200
264
226
(59966)
(51399)
(44974)
Yes
Yes
450/250
400/200
400/200
Viessmann
Low-loss
Temp.
Sensor
Required*2
40
(22)
25
Optional
Viessmann
Low-loss
Temp.
Sensor
Required*2
40
(22)
50
Yes
Yes
74
Yes
Yes
99
Yes
Yes
124
Yes
Yes
Yes
Yes
173
Yes
Yes
198
Yes
Yes