Positioning / modifications
Corrosion protection
Care
Service
4
Installation information /
Maintenance information
- Your gas condensing boiler should only be installed and modified
by an approved heating contractor, as only they have the essential
knowledge to carry out such work.
- Never modify flue gas components.
- Never close or restrict the ventilation apertures in doors or walls
when operating the boiler in open flue mode; only start the boiler
when the flue has been fully installed.
- For operation in balanced flue mode, only take the appliance into
use if the balanced flue system has been fully installed and the
wind protector is not covered up.
- The gas condensing boiler may only be installed in rooms that are
protected from frost.
- Never isolate the appliance from the power supply when outside
temperatures fall below zero, otherwise there is a risk of the system
freezing up.
- Never modify the drain or the safety valve.
Caution - failure to observe this rule may lead to a risk of fire
as well as a risk of destruction, poisoning or explosion!
Do not use or store explosive and/or flammable materials, e.g.
petrol, thinners, paints, paper etc. inside the boiler room!
Never use or store sprays, solvents, chlorinated cleaning agents,
paints, adhesives, etc. in the vicinity of the gas condensing boiler.
Under unfavourable conditions, these materials may lead to corrosion
in the gas condensing boiler and the flue system. Ducted vents routed
through a roof may also contain corrosive vapours. For that reason,
maintain a sufficiently large distance to the air/flue gas terminal (minimum
recommendation: 5 m).
Clean the casing with a damp cloth and mild detergent.
The components inside the gas condensing boiler may only be cleaned
by a heating contractor.
NB - only the heating contractor offers the required
knowledge and expertise!
- The user is responsible for arranging a regular service of the system,
in order to ensure the reliable and safe function of the gas condensing
boiler.
- Your gas condensing boiler should be serviced annually.
- Maintenance is explicitly detailed in the installation instructions.
- Isolate the appliance from the power supply before any maintenance
work.
- After a service and before the gas condensing boiler is returned into
use, check that all components that were removed for maintenance
have been refitted correctly.
- We recommend you arrange a maintenance contract with an approved
heating contractor.