Adjustment Procedures - Integra DTA-9.4 Service Manual

Seven channel amplifer
Hide thumbs Also See for DTA-9.4:
Table of Contents

Advertisement

QQ
3 7 63 1515 0

ADJUSTMENT PROCEDURES-1

POWER SUPPLY VOLTAGE ADJUSTMENT
When adjustment?
Replace the NAPS-7789 (secondary power supply PC board)
Notes
No load and No signal input.
How to adjustment?
1. Remove the top cover.
2. Connect a DC volt meter to the P108 Test point on the NADG-7313)
3. Connect the power supply card to a wall outlet.
4. Power On the unit.
Adjust the R139 trimming resistor so that the reading of DC voltmeter becomes standard value.
5.
Standard value : 53.6
6. Wait for five minutes.
7. Check the voltage of P108 again. If reading of a voltmeter is outside a standard, will adjust again.
8. Power Off.
9. Remove a DC voltmeter.
TE
L 13942296513
Front side
www
.
http://www.xiaoyu163.com
0.4 V
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Q Q
3
6 7
1 3
1 5
Measuring point
Adjustment point
R139 Trimming resistor
co
.
9 4
2 8
0 5
8
2 9
9 4
2 8
DC voltmeter
m
DTA-9.4
9 9
9 9