• Display provided when Self-Diagnos-
tic Function started
When the monitor is connected, the list of main menu
items is displayed of the monitor screen as shown below.
(This list remains on display until the self diagnostic
function is cancelled.)
The FL display of the main unit displays the protection
function history data and the version (1 alphabet) and the
self-diagnostic function menu [sub-menu (THR ALL) of
main menu No.1 DSP THROUGH] a few seconds later.
When there is no history of protection function:
Opening message / オープニング表示
Version (1 alphabet)
バージョン (英1文字)
NO PROTECT
When there is a history of protection function:
Cause: The voltage in the power supply section is abnormal.
Supplementary information: The abnormal voltage is
displayed in % based on 3.3V as 100%.
Turning on the power without correcting the cause will
trigger the protection function to work 1.5 second later to
shut off the power supply.
DIAGNOSTIC MENU
1.DSP THR
11.DOCK TEST
2.RAM THR
12.XM TEST
3.PRO LOGIC
13.DAB TEST
4.MIC CHECK
14‾16.HDMI
5.VFD CHECK
17.VIDEO CONV
6.MAN' LTEST
18.MODEL
7.RS232C
19.VER/SUM
8.PRESET
20.DATE
9.AD CHECK
21.DSP CHECK
10.IF STATUS
After 5 seconds / 5秒後
A
PS PRT:000 A
Voltage display in %
電圧の%表示
P2 PRT:000 A
P3 PRT:000 A
YSP-4000/YSP-40D/HTY-7040
● ダイアグ起動時の表示
モニターを接続してある場合は、モニターの画面に下図の
ようにメインメニューの一覧が表示されます。 (ダイアグ
を解除するまで、この表示が保持されます)
本体のFLディスプレイにプロテクション履歴情報とバージョ
ン (英1文字) が表示され、数秒後にダイアグ (メインメニュー
No.1 DSP THROUGHのサブメニューTHR ALL) になります。
プロテクション履歴がない場合:
Main menu display / メインメニュー表示
1.DSP THR ALL
プロテクション履歴がある場合:
Version (1 alphabet)
バージョン (英1文字)
原因: 電源部の電圧が異常。
補足: 異常時の電圧の状態を、3.3Vを100%とした値で%
表示します。
異常状態のまま電源オンすると、1.5秒後にプロテクショ
ンがかかり、電源が切れます。