4.6.7. Blurred Image
A. Typical faulty images
B. Troubleshooting procedure
Step
Cause
1
Humidity of the circumstances and paper.
2
T2 transfer voltage is low.
3
Connection between HVPS and THV is incorrect.
4
HVPS operates abnormally.
Copyright© 1995-2013 SAMSUNG. All rights reserved.
Action
Change the paper with new and better grade.
Turn up the T2 transfer voltage.
(Refer to 4.4.6.9.)
Check if the connection between T2 high voltage
terminal and HVPS THV terminal is correct.
Check if the connection of HVPS and ITB is correct.
If not, replace HVPS or ITB.
Replace HVPS
(Refer to 3.3.3.)
4. Troubleshooting