OUTLINES AND DIMENSIONS

INDOOR UNIT
PLA-RP35BA
PLA-RP100BA
PLA-RP71BA2
20~45
Fresh air
intake hole
Branch duct hole
Suspension bolt
M10 or W3/8
1
2
Suspension bolt
lower edge
Control wire entry
Air intake grille
M
Indoor unit
Ceiling
Grille
Obstacle
1500mm
or more
PLA-RP50BA
PLA-RP125BA
PLA-RP100BA3
Ceiling hole
860~910
810
Suspension bolt pitch
160
Remote controller
terminal block
Indoor unit/Outdoor unit
connecting terminal block
Indoor power supply
terminal block(Option part)
187.5
160
840
60
284
377
Power supply wire,
Indoor unit/Outdoor unit
connecting wire entry
597
Air intake hole
M
M
M
500
83
Air outlet hole
950
Indoor unit
3000mm or more
1800mm or more
from floor
For high
attachment
Floor
PLA-RP60BA
PLA-RP125BA2
20~45
Branch duct hole
(
Connected the attached
Drain pipe
connected to VP-25
flexible pipe or socket.
Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.
In case of standard grille : PLP-6BA / PLP-6BAMD
Ceiling
Grille
Drain hole
In case of auto-grille : PLP-6BAJ
Drain pump clean hole
and Drain emergency
In case of wireless remote controller : PLP-6BALM Auto grille
drainage hole
Emergency operation
Auto vane
switch<Cooling>and
(Air outlet)
Emergency Up/Down switch<Up>
Receiver
Vane motor
Note 1. Please choose the grille from a standard grille, auto-grille.
36
2. As for drain pipe, please use VP-25(O.D. 32 PVC TUBE).
Drain pump is included.
Max. lifting height is 850mm from the ceiling.
3. As for suspension bolt, please use M10 or W3/8.
(Procured at local site)
4. Electrical box may be removed for the service purpose.
Make sure to slack the electrical wire little bit for control/ power wires connection.
5. The height of the indoor unit is able to be adjusted with the grille attached.
6. For the installation of the optional high efficiency filter or optional multi-functional casement.
1) Requires E or more space between transom and ceiling for the installation.
2) Add 135 mm to the dimensions marked on the figure.
3) The optional high efficiency filter must be used jointly with optional multi-functional casement.
7. When installing the branch ducts, be sure to insulate adequately.
Otherwise condensation and dripping may occur.
(It becomes the cause of dew drops/water dew.)
8. As for necessary installation/service space, please refer to the left figure.
Models
PLA-RP35/50BA
Refrigerant pipe
··· 6.35
Flared connection
···1/4 inch
Refrigerant pipe
PLA-RP60BA
6.35 /
Flared connection
1/4 inch/3/8 inch
(compatible)
PLA-RP71BA
Refrigerant pipe
PLA-RP71BA2
··· 9.52
PLA-RP100,125BA
Flared connection
PLA-RP100BA3
···3/8 inch
PLA-RP125,140BA2
24
PLA-RP71BA
PLA-RP140BA2
Detail connecting of branch duct(Both aspects)
90
100
100
350
175
Burring hole pitch
Detail drawing of fresh air intake hole
Burring hole
Burring hole pitch
3- 2.8
125
)
Cut out hole
100
Ceiling
Air intake grille up/down discharge
Emergency operation
switch<Heating>and
Emergency Up/Down switch<Down>
L.L Filter
DEFROST/STAND BY lamp
Operation lamp
A
B
1
2
Refrigerant pipe
··· 12.7
80
Flared connection
···1/2 inch
9.52
241 258
87
Refrigerant pipe
··· 15.88
Flared connection
···5/8 inch
85 77
281
298
Unit : mm
90
Cut out hole
14- 2.8
Burring hole
150
Cut out hole
Ceiling
Air intake grille
C
D
E
74
400
440