Gas Connection - Baumatic B602.1BL/W User Manual

Table of Contents

Advertisement

Gas connection

Important information
o This oven is supplied to run on natural gas only and cannot be
o Conversion for use on LPG and other gases must only be
o The oven must be installed by a qualified person, in accordance
o Failure to install the appliance correctly could invalidate
o In the UK, only CORGI registered installers are authorised to
Ventilation requirements
o The room containing the oven should have an air supply in
o The room must have opening windows or equivalent; some
o If the room has a volume between 5 and 10m³, it will require an
o If the room has a volume of less than 5m³, it will require an air
o If there are any other fuel burning appliances in the same room
Downloaded from
www.Manualslib.com
This appliance must be installed by a competent
person in accordance with the current versions of
the following UK (United Kingdom) or ROI (Republic
of Ireland) Regulations and Safety Standards or
their European Norm Replaceme
used on any other type of gas without modification.
undertaken by a qualified person. For information on the use of
other gases, please contact the Baumatic Technical Department.
with the current edition of the Gas Safety (Installation and Use)
Regulations and the relevant building/I.E.E. Regulations.
Baumatic's guarantee and lead to prosecution under the
regulations quoted above.
undertake the installation and service work, in compliance with
the above regulations.
accordance with the current edition of BS 5440: Part 2:
rooms may also require a permanent vent.
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.
vent of 100cm² (effective area).
the current edition of BS 5440: Part 2: should be consulted to
determine air vent requirements.