Installation Location; Technical Data - AEG X-SLIM 35 EC Operation And Installation Instructions Manual

Shower water heater
Table of Contents

Advertisement

12
Installation Instruction
1.6 Regulations and Provisions
- Regulations of the local power
supply company should be
observed.
- Regulations of the water supply
company should be observed
- Read & study the technical data.
- Install the unit vertically on the
wall.
- Electrical connection to be
secured.
The device must be
capable of being isolated
from the mains, for example by
fuses, with an isolating distance of
at least 3.5 mm. in all poles.

1.8 Technical Data

Type
Norminal capacity
Design
Min. water pressure to activate unit
Water connection
Dimension (W x H x D)
Weight
Electrical connection
Recomended circuit breaker
Recomended cable size
Rated power (kW)
(Sqmm)
Rated current (A)
220 V
230 V
for the user and the qualified installer

1.7 Installation location

The shower unit is to be
installed in a closed, frost-
free room (disconnected units are
to be stored in a frost-free location,
since there will always be some water
left in the unit) The shower unit is to
be installed vertically on a wall (water
connection downwards).
The outlet must not be
connected to any tap or
fitting other than those specified.
35 EC
l.
0.15 bar / 0.015 MPa
G ½" (External Thread)
mm.
kg.
1/N/PE/AC 220...240 V.
20 A.
2.5-4
kW - A
3.5 - 15.9
3.8 - 16.5
45 EC
0.35
Open
342 x 216 x 73
1.8
25 A.
2.5-4
kW - A
4.5 - 20.5
4.9 - 21.3