Summary of Contents for AEG X-SLIM 35 EC

  • Page 1 OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC...
  • Page 3 General information The chapter Operation is intended for users and qualified installer. The chapter Installation is intended for qualified installer. Please read carefully Read these instruction carefully before using the appliance and retain them for future reference. If the appliance is passed on to a third party please hand these instructions to the new user.
  • Page 4 Installation Instruction for the qualified installer Dimension Cable 216 mm. 73 mm. 100 mm. Fig 1 Fig 3 Wall Mounting Wiring diagram Flow SW. A - Heating Element B - X-Slim-PC Front PCB C - ELCB D - X-Slim-PC Control E - Thermal Cut-Out 220-240 VAC.
  • Page 5 Installation Instruction for the user and the qualified installer 1. Operation and installation 1.2 The essentials - in brief a. Water valve instruction b. Rotary control for 1.1 Description of the unit. temperature adjustment The X-SLIM is a slim and pressure- c.
  • Page 6: Important Information

    Installation Instruction for the user and the qualified installer 1.3 Important information How to test : When the ELCB test button (F) is pressed the ELCB Reset (E) Button The unit must not be put under pressure. The outlet will drop. When the reset button (E) of the unit is also used as a vent.
  • Page 7 Installation Instruction for the user and the qualified installer 1.4 Detailed description 12. ELCB test button 1. Uper fixing hole (Fig 1) 13. Cold water connection 2. Lower fixing hole (Fig 1) 14. Hot water connection for 3. Depth for mounting screw(Fig 2) shower hose 4.
  • Page 8 Installation Instruction for the user and the qualified installer 1.5 Installation Instruction - Insert the wall plugs and screw make sure insertion depth is Switch off main breaker correct (Fig 2 number 3). for water heater. - Ensure that the ELCB is switched off.
  • Page 9 Installation Instruction for the user and the qualified installer - The unit must be installed with a circuit breaker The unit must be earthed (see recommended circuit properly (see circuit diagram breaker size in technical data (Fig 4)). table). - Guide the unit over the wall securing screws and slide it downwards.
  • Page 10 Installation Instruction for the user and the qualified installer - Straighten the unit and tighten the screws. Fig 16 Fig 18 - Connect the electrical supply - Fit the cover and secure with from cover into the PCB control. the screw. Fig 17 Fig 19...
  • Page 11 Installation Instruction for the user and the qualified installer - Turn the rotary control to the “off” - Fit the cold water pipe thoroughly position. (Fig 7 number 20). Fig 22 Fig 20 - Fit the filter and silicone gasket - Fit the shower accessories to (Fig 7 number 17, 18).
  • Page 12 Installation Instruction for the user and the qualified installer 1.6 Regulations and Provisions 1.7 Installation location - Regulations of the local power The shower unit is to be supply company should be installed in a closed, frost- observed. free room (disconnected units are - Regulations of the water supply to be stored in a frost-free location, company should be observed...
  • Page 13 Operation Instruction for the user and the qualified installer 2. Pre-operation 4. Care and Maintenance (Only to be carried out by a qualified installer). When carrying out any work, switch off the circuit braker Before turning on the power, to isolate the electrical power and turn the rotary knob to the cutt off the water connection.
  • Page 14 Operation Instruction for the user and the qualified installer If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 6. Service note Handing over the unit - Explain to the user how the unit works and familiarize them with its function.
  • Page 15 Fault elimination for the user 8. Fault elimination for the user Fault Cause Rectification No hot water despite water - The water flow volume - Increase flow volume flow through the unit. required for the unit to turn it on has not been reached.
  • Page 16 Material: Green Read Paper 75 g. Plastic bag : 7 x 11 INCH Part no. 7901-299525 Part name : Operating instruction X-slim (En-Th) Rev.01 Product code : X-SLIM 35 EC (AEG) : 232747 / X-SLIM 45 EC (AEG) : 232748...