Serial Number Clock / Data - Wiegand Interface; Id Number - Ascii Format Rs485 - Cerpass Reader Protocol; Id Number - Ascii Format Rs485 - Uci Reader Protocol - Siemens AR6181-MX Installation And Configuration Manual

Table of Contents

Advertisement

Configuration parameters
10.2.4 Serial number
10.2.5 ID number – ASCII format
10.2.6 ID number – ASCII format
38
Siemens Building Technologies
Fire & Security Products
Clock / Data – Wiegand interface
The unique serial number is transferred as a decimal equivalent.
DIP switch
DIP1 . . DIP3 = off, DIP4 = 0, DIP5 = 1, DIP6 = 0, DIP7/DIP8 = 0
Parameter:
Transponder:
UID_OUT with UID_START, UID_LNG
UID_MASK, UID_PATTERN
PIN:
No parameters (PIN length is = 8, fixed)
General:
CARD_TEC, TAG_BEEP, TAG_LED, CONFIG_CARD
Transferred:
ID card data:
Card number in BCD format (4-bit), 13 digits, aligned right, filled with zeros
Output via Wiegand interface; not a Wiegand-conforming data format!
PIN:
see Setting
RS485 – CerPass reader protocol
The ID number / card number personalized in ASCII format is transferred.
DIP switch
DIP1 . . DIP4 = reader address, DIP5 = 0, DIP6 = 1, DIP7 = 1, DIP8 = 0
Parameter:
Transponder:
ID_START, ID_LEN
Direct:
Indirect: MF_MAD, MF_AID1, MF_AID0 (Mifare – MAD)
MF_BLOCK
PIN:
PIN_MODE, PIN_BUF (default = 6)
General:
CARD_TEC, TAG_BEEP, TAG_LED, CONFIG_CARD, A_ID
MF_BLOCK, MF_KEY_TYPE, MF_KEY_NO
MF_UL_BLOCK
SL_BLOCK
Transferred:
ID card data:
16 characters in ASCII format of which 13 are ID card number characters,
aligned left, filled with zeros (0x30) – (telegram identifier: Kg)
PIN:
see Setting
RS485 – UCI reader protocol
The ID number / card number personalized in ASCII format is transferred.
DIP switch
DIP1 . . DIP4 = reader address, DIP5/DIP6 = 0, DIP7 = 1, DIP8 = 1
Parameter:
Transponder:
ID_START, ID_LEN
Direct:
Indirect: MF_MAD, MF_AID1, MF_AID0 (Mifare – MAD), MF_BLOCK
Interface:
UCI_CODING (default = 0)
PIN:
PIN_MODE, PIN_BUF (default = 7)
General:
CARD_TEC, TAG_BEEP, TAG_LED, CONFIG_CARD, A_ID
MF_BLOCK, MF_KEY_TYPE, MF_KEY_NO
MF_UL_BLOCK
SL_BLOCK
Transferred:
ID card data:
16 characters in ASCII format of which 13 are ID card number characters,
aligned left, filled with zeros (0x30)
PIN:
see Setting
PIN input Clock / Data - Wiegand Interface in chapter 10.3.4.
MF_BLOCK or MF_UL_Block or SL_BLOCK
PIN input CerPass Reader Protocol in chapter 10.3.1.
MF_BLOCK or MF_UL_Block or SL_BLOCK
PIN input UCI Reader Protocol in chapter 10.3.2.
Mifare Standard
Mifare UltraLight
my-D proximity
Mifare Standard
Mifare UltraLight
my-D proximity
12.2004

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar6182-mx

Table of Contents