Parameter
LED
Tray Icon
Hide Password
Admin Password SUMMIT
Auth Timeout
Certs Path
Ping Payload
Ping Timeout ms 5000
Ping Delay ms
Note: Tap the Commit button to save changes. If this panel is closed before tapping the Commit button, changes are
not saved!
11 - 16
Default
Function
Off
The LED on the wireless card is not visible to the user when the wireless card
is installed in a sealed mobile device.
Options are: On, Off.
This parameter cannot be changed.
On
Determines if the Summit icon is displayed in the System tray.
Options are: On, Off
On
When On, the Summit Config Utility masks passwords (characters on the
screen are displayed as an *) as they are typed and when they are viewed.
When Off, password characters are not masked.
Options are: On, Off.
A string of up to 64 alphanumeric characters that must be entered when the Ad-
(or Blank)
min Login button is tapped. If Hide Password is On, the password is masked
when typed in the Admin Password Entry dialog box. The password is case sen-
sitive. This value is masked when the Admin is logged out.
Options are: none.
8 seconds
Specifies the number of seconds the Summit software waits for an EAP authen-
tication request to succeed or fail.
If the authentication credentials are stored in the active profile and the authen-
tication times out, the association fails. No error message or prompting for cor-
rected credentials is displayed.
If the authentication credentials are not stored in the active profile and the au-
thentication times out, the user is again prompted to enter the credentials.
Options are: An integer from 3 to 60.
System
A valid directory path, of up to 64 characters, where WPA Certificate Authority
and User Certificates are stored on the mobile device when not using the Win-
dows certificates store. Make sure the Windows folder path currently exists be-
fore assigning the path in this parameter. See Certificates for instructions on
obtaining CA and User Certificates. This value is masked when the Admin is
logged out.
Options are: none.
For example, when the valid certificate is stored as My Computer/System/MY-
CERTIFICATE.CER, enter System in the Certs Path text box as the Windows
folder path.
32 bytes
Maximum amount of data to be transmitted on a ping.
Options are: 32 bytes, 64, 128, 256, 512, or 1024 bytes.
The amount of time, in milliseconds, that a device will be continuously pinged.
The Stop Ping button can be tapped to end the ping process ahead of the ping
timeout.
Options are: Any number between 0 and 30000 ms.
1000
The amount of time, in milliseconds, between each ping after a Start Ping button
tap.
Options are: Any number between 0 and 30000 ms.