Installation Instructions - Frigidaire PGLEF385EB3 Use & Care Manual

Electric
Table of Contents

Advertisement

Available languages

Available languages

Installation and service must be performed by a qualified technician.
IMPORTANT: Save for the local electrical inspector's use.
Read and save these instructions for future reference.
Clearances and Dimensions
a. Provide adequate clearances between the range and adjacent combustible surface (1.3cm (1/2") to the cabinet side walls
and the rear wall).
b. Location—Check location where the range will be installed. Check for proper electrical supply and the stability of floor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid
and level.
FRONT
VIEW
76.2 cm (30")
Minimum
Minimum to
1.3 cm
wall on either
(1/2")
side of range.
91.4 cm
(36")
* 76.2 cm (30") Minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal
cabinet; or 61 cm (24") Minimum when bottom of wood or metal cabinet is protected by not less than 0.64 cm (1/4") flame
retardant millboard covered with not less than 0.038 cm (0.015") stainless steel, 0.061 cm (0.024") aluminum or 0.051 cm
(0.020") copper. 1.3 cm (1/2") clearance is the minimum for the rear and sides of the range. Follow all dimension requirements
provided above to prevent property damage, Potential fire hazard, and incorrect countertop and cabinet cuts.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 12.7 cm (5") beyond the bottom of the cabinets.
Electrical Hook-Up
This appliance must be connected to a grounded 120/240 volt or 120/208 volt Range
outlet. If no outlet is available, have one installed by a qualified electrician.
Location
Set your new range 1.3 cm (1/2") away from the rear wall and line it up with the kitchen
counters. Make sure there is at least 1.3 cm (1/2") of clearance between each side of the
range and the kitchen counters. Allow 7.6 cm (3") min. clearance between your range and
the refrigerator, if they are side by side.
Circuit Protection (Models with electric oulet(s))
As a protection against surcharge, a 15 amp, 120 volt breaker is provided for each of the electric outlet(s) (2 max.) located on
top or underneath of the control panel. Models with no electric outlet have no breaker.

Installation Instructions

VIEW
C
*
Minimum to
45.7 cm
cabinets on
Maximum depth for
(18")
either side of
cabinets above
range.
range top.
B
A
SIDE
76.2 cm (30")
33 cm
(13")
122 cm (48")
Maximum
114.3 cm (45")
Door Open
5
DIMENSIONS
B
C
78.7 cm (31")
76.2 cm (30")
66 cm (26")
A
91.4 ± 0.3 cm
(36 ± 1/8")

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pglef385es3

Table of Contents