Nominal Size - Tons
Outdoor Unit Model No.
Number of Zones
1
AHRI
Ratings
High Temperature Heating - Btuh
Low Temperature Heating - Btuh
Energy Star
Ambient Temperature Range - °F
Sound Data (dBA)
Charge furnished (R-410A)
Refrigerant
Maximum line length with furnished charge (per zone) - ft.
Additional charge required per ft. - oz.
Compressor
Refrigerant oil charge - oz.
Liquid+Gas+Gas pipe (fl are)
Connections - in.
Maximum length for all rooms - ft.
Maximum length for one indoor unit - ft.
Maximum height
Outdoor unit higher than indoor
difference between
indoor unit and
Outdoor unit lower than indoor
outdoor unit
Maximum difference in level between indoor units - ft.
Outdoor
Fan
Outdoor Coil
Tube outside diameter - in.
Design Pressure
Shipping Data
Electrical Characteristics - 60 Hz - 1 Phase
2
Maximum Overcurrent Protection (amps)
3
Compressor Rated load amps
Outdoor Fan Motor
NOTE - Per AHRI, the certifi ed ratings for systems are valid for all combinations of indoor units with the specifi c outdoor units listed above and in the AHRI Directory of
Certifi ed Equipment. Please visit
http://www.ahridirectory.org
1
Ratings are AHRI certifi ed to AHRI Standard 210/240-2008;
• Cooling Ratings - 80°F dry bulb/67°F wet bulb entering indoor coil air and 95°F dry bulb/75°F wet bulb outdoor air temperature.
• High Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 47°F dry bulb/43°F wet bulb outdoor air temperature.
• Low Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 17°F dry bulb/15°F wet bulb outdoor air temperature.
NOTE - Extremes of operating range are plus and minus 10% of line voltage.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Adaptors are furnished for the gas pipe connections:
036 - (3) 3/8 x 1/2 in. and (1) 1/2 x 3/8 in.
048 - (3) 3/8 x 1/2 in., (2) 1/2 x 3/8 in., (2) 1/4 x 3/8 in. and (2) 1/2 x 5/8 in.
System Type
Cooling - Btuh
SEER
EER
HSPF (Region IV)
AHRI Reference Number
Cooling
Heating
Cooling
Heating
No. and Type
Refrigerant oil type
Low ambient cut-off
unit - ft.
unit - ft.
(No.) Diameter - in.
Total air volume - cfm
rpm
Number of rows
Fins per inch
Fin type
Tube type
Net face area - ft.
2
PSIG
Net/Shipping weight (lbs.)
ELECTRICAL DATA
Minimum circuit ampacity
Rated load amps
Output - W
for further details and latest updates.
3
MPA036S4M-1P
Up to 4
Ducted
Non-Ducted
34,000
36,000
36,000
36,000
24,400
23,400
15.00
18.00
8.20
8.80
9.3
10.0
8129615
8129614
Yes
5 - 122
–13 - 76
62
64
7 lbs. 15 oz.
25
0.161
Twin-Rotary
FV50S
36.2
(4) 1/4 + (3) 3/8 + (1) 1/2
197
98
33
49
33
(1) - 22
2240
950
2.6
15
Hydrophilic aluminium
5/16
Rifl ed copper tubing
6.42
550/340
162 / 174
208/230V
45
27
19.5
1.30
120
4
MPA048S4M-1P
Up to 5
Ducted
Non-Ducted
42,000
42,000
51,000
49,000
31,800
31,200
18.00
20.00
11.00
12.50
9.5
10.0
8129617
8129616
No
5 - 122
–13 - 76
58
62
9 lbs. 8 oz.
25
0.161
Twin-Rotary
FV50S
47.3
(5) 1/4 + (3) 3/8 + (2) 1/2
246
98
33
49
33
(2) - 20
(2) 4240
(2) 800
2
15
5/16
14.33
550/340
218 / 245
208/230V
50
29
22
(2) 0.9
(2) 85