Download Print this page

Instrument Familiarization; Overload Indication; Measuring Procedures - Amprobe HD110C User Manual

Hide thumbs Also See for HD110C:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
ACROSS a voltage source. Check fuse first.
Never replace a fuse with one of a different rating.
Do not operate instrument in an explosive atmosphere (flammable gases, fumes,
vapor, dust.)
Do not use this or any piece of test equipment without proper training
CRT SERVICE SAFETY REMINDER: A potential danger exists when measuring voltages in
the horizontal output and damper stages of CRT equipment. (High voltage transients greater
than 8000 V). Refer to your CRT service manual for proper servicing instructions.

Instrument Familiarization

Your shipping carton should include the multimeter, a holster with Magne-Grip hanging strap, one test
lead set (one black, one red) threaded alligator clips, one 9 V battery (installed), one 2 mm hex wrench
(inside holster) and this manual. If any of the items are damaged or missing, immediately return the
complete package to the place of purchase for an exchange.
Protective Holster
The holster/tilt stand protects the meter form accidental falls and provides greater ease of use. Both test
lead probes can be attached to the holster for storage. One probe can be attached for measurement,
holding the meter with probe in one hand and the second probe in the other hand.

Overload Indication

Overload Indication: (input exceeds meter's highest range) and Display Overload (input
exceeds selected range) are both signaled by a 1 displayed on the left side of the LCD.
In the volts or amperage ranges Display Overload can be corrected by selecting a
higher range to display the input reading. If the highest range is selected and the overload indication
continues, this is now an Input Overload. Remove the test leads from the circuit immediately as input
exceeds the meter's rated capability.
Note: In both instances, the overload indication is normal in the OHMS and Continuity/Diode ranges to
indicate an open circuit. Function Error is signaled a by continuous tone when a test lead is placed in
either the 2 A jack and the selector switch is not in the correct current range. If the meter is connected
to a voltage source with test leads set for current, very high current could result. All current ranges are
protected with fast acting fuses.
Battery Low: When the battery low indicator is displayed the battery has less than 50 hours operation
and the accuracy of the meter can no longer be guaranteed.

Measuring Procedures

Turn the meter on by turning the function/range switch away from OFF and selecting the parameter
you want to measure. If the parameter selected has more than one range position, the display will
indicate the range by a changing position of the decimal point. Always select the highest range if the
maximum potential reading is not known. Then turn the selector switch down in range to obtain the
best resolution reading.
1.
When connecting or disconnecting test leads to a circuit, always turn off power to device or
circuit being tested and discharge all capacitors.
2.
Strictly observe the max input limits.
3.
Do not change functions while test leads are connected to circuit.
3

Advertisement

loading