Lennox Hearth Products VINTAGE VINT-DVS-U Installation And Operation Manual
Lennox Hearth Products VINTAGE VINT-DVS-U Installation And Operation Manual

Lennox Hearth Products VINTAGE VINT-DVS-U Installation And Operation Manual

Elite series

Advertisement

Quick Links

P/N 775227M REV. F 09/2011
Portland
US
Ce manuel d'installation est disponible en francais, s implement en faire
la demande. Numéro de la pièce 775227CF.
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consulta-
tion ultérieure.
OTL Report No. 50-S-11b-5

INSTALLATION AND OPERATION

Direct-Vent
VINTAGE™
MODELS
VINT-DVS-U
AVERTISSEMENT
UNE SURFACE VITRÉE CHAUDE PEUT
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT: Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire
au minimum le risque d'incindie ou d'explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
SDVCS
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products VINTAGE VINT-DVS-U

  • Page 1: Installation And Operation

    INSTALLATION AND OPERATION Direct-Vent VINTAGE™ P/N 775227M REV. F 09/2011 MODELS Portland OTL Report No. 50-S-11b-5 VINT-DVS-U SDVCS Ce manuel d’installation est disponible en francais, s implement en faire la demande. Numéro de la pièce 775227CF. WARNING AVERTISSEMENT HOT GLASS WILL UNE SURFACE VITRÉE CHAUDE PEUT CAUSE BURNS.
  • Page 2: Table Of Contents

    Vertical Terminations ..........16 your new gas stove. Horizontal Vent Termination Locations ....... 17 Thank you for selecting a Lennox Hearth Products gas stove as Gas Line Installation ............18 the answer to your home heating needs. Gas Pressure Requirements ........18 LP and Natural Gas Supplies ........
  • Page 3: Safety And Warning Information

    IMPORTANT SAFETY AND WARNING AVERTISSEMENT INFORMATION On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à prox- WARNING imité. Young children should be carefully supervised when they are in the same room as the appliance. Tod- WARNING dlers, young children and others may be susceptible Any safety screen or guard removed for servicing...
  • Page 4  T his appliance is only for use with the type of gas indicated on  F OR YOUR SAFETY do not install or operate this appliance without rating plate. This appliance is not convertible for use with other first reading and understanding this manual. Any installation or gases, unless a certified kit is used.
  • Page 5: Homeowner - Attaching Safety In Operation Warnings

    3. If you are unable to locate the labels, please call (Figure C). Choisissez la langue qui est principale­ Lennox Hearth Products o al distribuidor de Lennox Lennox Hearth Products or your nearest Lennox ment parlée dans la résidence du propriétaire.
  • Page 6: Orifice Size/Altitude Adjustment

    If there are any questions or if you need further These appliances are approved for installation in the US state of Mas­ substantiation either write to or call your Lennox Hearth Products dealer. sachusetts if the following additional requirements are met: If you have further questions, please contact Lennox Hearth Products.
  • Page 7: Pre-Installation

    Manufactured (mobile) home conversion kit. Only Lennox Hearth Products conversion kits can be used to Natural gas (NG) or propane (LP) convert from NG to LP or LP to NG. Contact your Lennox Hearth Products Bedrooms dealer for details. Optional wall­mounted or remote thermostat...
  • Page 8: Preparing Your Stove For Installation

    4­3/16” up from the base of the unit. and may create a serious fire, health, or other safety hazard. The Lennox Hearth Products warranty will be voided if one of the fol­ Top View lowing occurs: •...
  • Page 9: Clearances To Combustibles

    Clearances to Combustibles Alcove dimensions Minimum clearances to combustible materials shown here are in inches The minimum width between alcove side walls is 30­1/2” (775mm). The (millimeters). See Pages 8 and 9 for pipe clearances. glass door lifts up to access the firebox on the stove. Therefore, if the stove is to be installed in an alcove, the alcove needs to be constructed to allow for removal of the glass door.
  • Page 10: Installation

    INSTALLATION Baffle and Log Set Installation Baffle The cast iron baffle is wrapped in foam and shipped between the outside of the firebox and the outer shell of the stove. Remove the foam and install the baffle in the rectangular hole in the top of the firebox. The baffle rests unsecured in the hole.
  • Page 11: Side Insert Installation

    Side-Insert Installation Follow these steps to install the cast iron inserts or your own custom stone inserts in this appliance: Upper Cast Piece Retainer 1. Remove the cast iron top and set it aside. 2. Remove the cast iron upper piece A ­ see Figure 14. Complete this step by unscrewing the (2) 5/32 hex­head screws labeled B in Figure 17.
  • Page 12: Vent Installation

    Vent Installation Minimum Components for Horizontal Installation: Horizontal Termination Kit which includes: enting This appliance has been tested and listed as a direct­vent heater • 1 6­5/8”x 6” Black Pipe system by OMNI­Test Laboratories, Portland, Oregon and is rec­ • 1 Riser Vent Terminal ommended for use with Security™...
  • Page 13: Vent Parts List

    Vent Parts List Horizontal Vent Installation Secure Vent direct­vent pipe by Security Chimneys* may be used with Venting terminals may not be recessed into a wall or siding. this appliance. Please see the lists below to verify the components avail­ able from each direct­vent pipe manufacturer.
  • Page 14: Snorkel Terminations

    Snorkel Terminations For installations requiring a vertical rise on the exterior of the building, 14­inch and 36­inch tall snorkel terminations are available. When us­ ing a snorkel, the stove can be vented directly out the back. There is a Framed Hole: vent starter collar fastened to the stove (to vent straight out the back), 9-1/4”x 10-1/4”...
  • Page 15: Flue Restrictors

    Flue Restrictors 4 3 2 1 The flue restrictor settings shown in Figures 26 and 27 are for typical installations and may need to be adjusted from standard to take into account other variables in the installation to achieve proper combustion. See Flue Restrictor Guidelines on this page to assist you in making a proper flue restrictor adjustment.
  • Page 16: Horizontal Terminations

    Horizontal Terminations Vertical Terminations The shaded areas in the diagram below show all allowable combinations The diagram below shows all allowable combinations of straight verti­ of vent configurations with horizontal terminations. Horizontal sections cal and offset to vertical vent configurations with vertical terminations. of pipe require 1/4”...
  • Page 17: Horizontal Vent Termination Locations

    Exterior Horizontal Vent Termination Clearance Requirements * See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9" in U.S. = 12" in Canada DETAIL D 3 ft.
  • Page 18: Gas Line Installation

    (LP) if a certified fuel pressure side. To check inlet pressure (with the appliance burning) conversion kit provided by Lennox Hearth Products is installed by a insert a small flat bladed screw driver into the tap and turn a half turn qualified service technician.
  • Page 19: Installer - Attaching Safety In Operation Warnings

    3. Si no puede encontrar las etiquetas, sírvase llamar a Lennox Hearth Products or your nearest Lennox taire. En cas de doute, collez l’étiquette en anglais. Lennox Hearth Products o al distribuidor de Lennox Hearth Products dealer to receive additional 3. Si vous ne trouvez pas les étiquettes, veuillez Hearth Products más cercano para recibir etiquetas...
  • Page 20: Operating Instructions

    OFF OR ATTEMPT TO REMOVE THE GLASS WHILE HOT. gas supply shut­off cocks are open. 5. Push in gas cock dial slightly and turn clockwise CAUTION: YOUR LENNOX HEARTH PRODUCTS GAS APPLIANCE “OFF.” MUST ALWAYS BE OPERATED WITH GLASS IN PLACE.
  • Page 21: Flame Color And Behavior

    12. Adjust the flame height (and heat output) by turning the flame Flame Height Control Gas Control Knob height knob clockwise for full flame and counter­ Knob (HI/LO) (Pilot / On / Off) clockwise for reduced flame. 13. Turn on the electric power to the appliance and set the blower to the desired air flow after it turns on when the appliance reaches operating temperature.
  • Page 22: Air Shutter Adjustment

    End View of Gas Valve An optional blower (part # 75194) may be installed on your stove to maximize heat distribution. See your Lennox Hearth Products dealer for Figure 33 blower information. The optional blower is equipped with a three­prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three­prong receptacle.
  • Page 23: Operating Options

    Operating Options Thermostat Wire Wire Size Maximum Length “On-Off” Switch, Thermostat Or Remote Control 12 Gage 100 Feet Your stove comes equipped with an “On/Off” rocker switch used to turn 14 Gage 64 Feet the burner on and off while the pilot light is on. The switch is a round 16 Gage 40 Feet rocker switch located behind the main control panel door.
  • Page 24: Maintenance And Servicing

    The viewing glass should be cleaned periodically (see Glass Door MAINTENANCE AND SERVICING Cleaning and Maintenance). Should repairs or maintenance of the stove require the disassem- WARNING bly of the vent/air intake system, the reassembly and resealing should be completed by a qualified service technician and follow Turn off gas and electrical power to the fireplace the instructions on Page 12 of this manual.
  • Page 25: Opening And Removing Door

    The replacement glass and gasket are available from your Lennox Hearth Products dealer. The glass is • Do not use abrasive cleaners. Never clean the neo­ceramic and alternative types must not be used.
  • Page 26: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 27: Replacement Parts

    Contact an Lennox Hearth Products dealer to obtain any of these parts. REPLACEMENT PARTS - VINT-DVS-U / SDVCS Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. Cat. No. Description WARNING H6031 Cassette Assembly, NG (if LP, also requires 75190...
  • Page 28: Accessories

    ACCESSORIES - VINT-DVS-U / SDVCS Misc. Cat. No. Model Description 75194 VINT-TET BLWR Blower (ref. Form #775202M) Product Reference Information 75195 VINT-TETN-MHK Mobile Home Install Kit (ref. Form #775204M) Cat. No. Description Ship. Ship. 75203 VINT-RVTC Rear Vent Top Cover Weight Volume RT-AC...
  • Page 29: Stove Labels

    SAFETY / LISTING LABEL - VINT-DVS-U / SDVCS 2011 2012 2013 2014 Part No./No. Pièce #36224 Rev. B, 02/2011 IGN 11-0831 LENNOX 11-0831 FRONT NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 30 LIGHTING LABEL - VINT-DVS-U / SDVCS Part No./No. Pièce #36224 Rev. B, 02/2011 IGN 11-0831 LENNOX 11-0831 BACK NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 31 NOTES...
  • Page 32: Product Reference Information

    Fuel Type (Check one) c Natural Gas c Propane Gas (LP) Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.