Disable Sleep Mode; To Disable Sleep Mode On Computer (Windows Xp); To Disable Sleep Mode On Computer (Windows Vista); Upload Data To Pc Software - Oregon Scientific WMR200 User Manual

Hide thumbs Also See for WMR200:
Table of Contents

Advertisement

Available languages

Available languages

If you have Windows Vista and User Account Control is ON (ticked):
i. In Select Installation Folder dialogue box, next to Folder text box (C:\
Progra
iles Oregon Scientific Weather OS , click Browse.
ii. To select a new location to save the program, select C:\Users\admin. {Or
click C: Drive, subfolder Users, subfolder admin.}
iii. Click on
(Create New Folder) icon.
iv. Type OS Weather and click OK.
v. In User Account Control dialogue box, click Allow.
vi. Continue with installation process.
4. During installation, Microsoft Visual C++ Redistributable Setup dialogue box
may appear. Select Repair and click Next.
5. Once Setup has been successfully completed, click Finish, then Close.
6. After successful installation, double click on
7. Click Display in Oregon Weather Station dialogue box.

DISABLE SLEEP MODE

To allow for continuous data updates, ensure Sleep Mode on computer is disabled.

TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS XP)

1. Right click on Desktop.
2. In context menu, click on Properties.
3. Click on Screen Saver tab in the Display Properties dialogue box.
4. Click on Power located at the bottom half of dialogue box.
5. In new dialogue box Power Options Properties, click on Power Schemes tab.
6. In Settings for Timers off (Presentation) power scheme section, under System
Standby option, choose Never in drop-down list.
7. Click Apply and then click OK.
8. Previous window will return. Click OK to confir

TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS VISTA)

1. Right click on Desktop.
2. In context menu, click on Personalize.
3. Click on Screen Saver link in the Personalize appearance and sounds dialogue
box.
4. Click on Change Power Settings located at the bottom half of window.
5. Select High Performance and click Change plan settings link.
6. Click Change advanced power settings link.
7. Click on
next to Sleep, in sub menu, click on
8. Click Setting link and select Never in drop-down list.
9. Click Apply and then OK.

UPLOAD DATA TO PC SOFTWARE

NOTE The USB is only used for uploading weather data. It cannot be used for
charging battery power.
1. After successful installation, double click on
2. Click Display in Oregon Weather Station dialogue box.
3. You will be prompted to select model number. Please select your model in the
drop-down list and refer to the i age ne t to your selection to confir
correct model.
4. Plug one end of the USB cable into the base station's USB port and the other end
into the PC's USB port.
5. Uploading will start immediately.
NOTE This product should be supplied by an identical USB port complying with the
requirements of Limited Power Source.
To clear records from the base station:
1. Press clock area
until DATA LOGGER is displayed.
2. Press and hold MEM.
3. All LED icons will light up and turn off consecutively (right to left). Delete process
is complete and successful after blinking of last icon
To learn more about how to utilize the functions available on the software, please
refer to PC Software Manual, downloadable from the software webpage.
IMPORTANT
ou
ust first successfully install software to access the P Software
Manual.
desktop shortcut.
and e it
next to Hibernate after.
desktop shortcut.
it is the
.
10
1. In the PC software homepage, click on MENU located at the top right hand corner
of software main webpage.
2. Select HELP from drop-down list. This will redirect you to a new webpage. Click
on
PC Software Manual.

SOFTWARE UPDATES

As we continually strive for improvement, the software will be updated from time to
time.
If there is a new version, the moment PC is connected to the internet, a dialogue box
informing of available software will appear.
1. Click OK.
2. After a few moments, File Download - Security Warning dialogue box will
appear. Click Run.
3. In the Internet Explorer - Security Warning, click Run.
4. Follow steps 3 - 7 from Install Software section.

RESET

Press RESET to return to the default settings.

PRECAUTIONS

o not sub ect the unit to e cessi e force, shock, dust, te perature or hu idity
o not co er the entilation holes with any ite s such s newspapers, curtains
etc.
o not i
erse the unit in water f you spill li uid o er it, dry it i
a soft, lint-free cloth.
o not clean the unit with abrasi e or corrosi e
o not ta per with the unit s internal co ponents This in alidates the
warranty.
Only use fresh batteries
o not
ages shown in this
anual
ay differ fro
When disposing of this product, ensure it is collected separately for special
treatment.
Place ent of this product on certain types of wood
finish for which Oregon Scientific will not be responsible
manufacturer's care instructions for information.
The contents of this
anual
ay not be reproduced without the per ission of the
manufacturer.
o not dispose old batteries as unsorted
waste separately for special treatment is necessary.
Please note that so e units are e uipped with a battery safety strip
strip fro
the battery co part ent before first use
NOTE The technical specifications for this product and the contents of the user
anual are sub ect to change without notice
NOTE Features and accessories will not be available in all countries. For more
information, please contact your local retailer.
SPECIFICATIONS
BASE STATION
Dimensions (L x W x H)
Weight
INDOOR BAROMETER
Barometer unit
Measuring range
Accuracy
Resolution
Altitude setting
Weather display
Memory
INDOOR TEMPERATURE
Temp. unit
Displayed range
Operating range
Accuracy
Comfort
Memory
Alarm
INDOOR RELATIVE HUMIDITY
Displayed range
Operating range
Resolution
Accuracy
Comfort
ediately with
aterials
i new and old batteries
the actual display
ay result in da age to its
onsult the furniture
unicipal waste
ollection of such
e o e the
149 x 198 x 47 mm (5.9 x 7.8 x 1.9 inches)
510 g (18 oz) without battery
mb/hPa, inHg and mmHg
700 – 1050mb/hPa
+/- 10 mb/hPa
1mb (0.0 inHg)
Sea level
User setting for compensation
Sunny, Clear night, Partly Cloudy, Cloudy,
Cloudy at night, Rainy and Snowy
Historical data and bar chart for last 24hrs
°C / °F
0°C to 50°C (32°F to 122°F)
-30°C to 60°C (-4°F to 140°F)
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
20°C to 25°C (68°F to 77°F)
Current, Min and Max temp.
Dew Point w/ Min and Max
Hi / Lo
2% to 98%
25% to 90%
1%
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
40% to 70%