Ac Manual Mode; No Ac Power Or Loss Of Ac Power; Ac Power Restored; Troubleshooting "No Ac" Fault - Norcold 1200 series Service Manual

Gas/electric refrigerators
Hide thumbs Also See for 1200 series:
Table of Contents

Advertisement

AC Manual Mode

In the AC Manual mode, AC power is the only heat
energy source selected by the controls. When AC
Manual Mode is selected:
1. The AC light flashes as the controls
start the search for AC power.
2. When AC power is detected, the AC light
remains on.

No AC Power or Loss of AC Power

If the controls do not sense the presence of AC power
or when AC power is lost in AC Manual mode, the
controls:
1. Display the "no AC" fault code.
2. Sound the audible alarm. The alarm is an
intermittent beeping tone. Pressing the MODE
pushbutton silences the alarm.
3. Record and store the "no AC" fault in diagnostics
nonvolatile memory fault history.

AC Power Restored

When AC power is restored, the controls:
1. Automatically restore AC Manual Mode operation;
however, the recorded fault history will not be
erased from memory.
2. Silence the alarm and clear then "no AC" fault
code from the display.

Troubleshooting "no AC" Fault

Use the following references to identify, troubleshoot,
and correct a no AC fault.
Page 13, "no AC" fault codes troubleshooting
flowchart.
Page 47, Diagnostic Mode, Screen 6 or pages 50-
51, Diagnostic Mode, Screens 5 and 8.
Refrigerator Service Manual
AUTO
AC
LP GAS
AUTO
AC
LP GAS
AC
www.norcold.com/cda

LP Manual Mode

In the LP Manual Mode, LP gas is the only heat
energy source selected by the controls. When the
controls shift to LP Manual mode:
1. The LP light flashes and the controls
start a 30 second trial-for-ignition.
2. When the controls sense a flame
the LP light remains on.

Flame Fails to Ignite or Flame Goes Out

If the controls do not sense a flame within the 30
second trial-for-ignition or the flame goes out, the
controls:
1. Shut off power to the solenoid gas valve.
2. Set "gas lock-out." See NOTE 3 below.
3. Sound an audible alarm. The alarm is an
intermittent beeping tone. Pressing the MODE
pushbutton silences the alarm.
4. Display a flashing visual warning, "no LP" (shown
below).
NOTE 3
AUTO LP mode remains in "gas lock-out" until a full
cooling cycle on AUTO AC is completed. "Gas lock-
out" can also be cleared by turning the refrigerator OFF
then back ON or by selecting the AUTO mode.
1200XX/120X-IMXX Models
AUTO
AC
LP GAS
AUTO
AC
LP GAS
LP GAS
43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

120-im series

Table of Contents