Datalogic Gryphon GFS4 series Quick Reference Manual
Datalogic Gryphon GFS4 series Quick Reference Manual

Datalogic Gryphon GFS4 series Quick Reference Manual

Fixed mount linear imager bar code reader
Hide thumbs Also See for Gryphon GFS4 series:

Advertisement

Gryphon™ GFS4XXX
Fixed Mount Linear Imager
Bar Code Reader
Quick Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic Gryphon GFS4 series

  • Page 1 Gryphon™ GFS4XXX Fixed Mount Linear Imager Bar Code Reader Quick Reference Guide...
  • Page 2 Datalogic representative. Electronic versions may either be downloadable from the Datalogic web- site (www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.
  • Page 3: Table Of Contents

    Table of Contents Setting Up the Reader ......................6 Select Interface - USB Interface ..............6 Mounting Bracket ......................8 Programming ........................10 Operating Modes ...................... 10 Exposure Modes ..................... 11 Technical Features ......................12 RS-232 Electrical Connections ..............14 LED and Beeper Indications ..................... 16 Button and LED Status ....................
  • Page 4 NOTES...
  • Page 5 Datalogic Product ("End User"). For purposes of this Agreement, any software that is associated with a separate end-user license agreement is licensed to you under the terms of that license agreement. Datalogic and End User hereby agree as fol- lows: 1.
  • Page 6 Software is protected by intellectual property laws and treaties. The license set forth in this Agreement does not transfer to End User any ownership of Datalogic's or its third party licensors' copyrights, patents, trademarks, service marks, trade secrets, or other intellectual prop- erty rights and End User shall have no right to commence any legal actions to obtain such rights.
  • Page 7 2) Datalogic controls the defense or settlement of the claim, and 3) End User cooperates fully with Datalogic in such defense or settlement. All notices of a claim should be sent to Data- logic Scanning, Inc., Legal Department, 959 Terry Street, Eugene, OR 97402.
  • Page 8 This provides our customers with the very latest in Datalogic software technology. The only exception to this policy is when the buyer has a signed contract with Datalogic that clearly defines the terms and conditions for making software/firmware changes in products shipped to the buyer.
  • Page 9 Unlike currently available products, the GFS4XXX uses the latest and fastest imaging technology and offers Datalogic’s Green Spot for targeting and good read feedback. The scanning technology is essentially the same as the Gryphon I 4100 family of linear imagers, with some adjustments made for read range and improved motion tolerance.
  • Page 10: Setting Up The Reader

    To simulate a Keyboard, scan the bar code below: Interface Selection: USB-KBD (GFS4170 model only ) To simulate an RS-232 Standard Interface scan the bar code below: Interface Selection: USB-COM (GFS4170 Model only) Download the correct USB COM driver from: http://www.datalogic.com. IMPORTANT Gryphon™ GFS4XXX...
  • Page 11 Setting Up the Reader Select USB Keyboard with alternate key encoding: USB Alternate Keyboard Select USB Keyboard for Apple computers: USB-KBD-APPLE Select RS-232 Wincor-Nixdorf: RS-232 Wincor-Nixdorf Quick Reference Guide...
  • Page 12: Mounting Bracket

    Setting Up the Reader Mounting Bracket The GFS4XXX can be mounted to a stationary surface using a bracket as shown below. Just attach to the bottom of the reader using screws, as shown in the next two figures. Figure 1. Mounting the bracket Gryphon™...
  • Page 13 Setting Up the Reader Figure 2. Bracket Attached Quick Reference Guide...
  • Page 14: Programming

    Programming Programming For your convenience, this guide includes the programming bar codes re- quired to configure the reader. If you aren't sure what programming options are in your reader, or you've changed some options and want the factory settings restored, scan the bar code below: Restore Default Settings Operating Modes...
  • Page 15: Exposure Modes

    Programming Operating Modes (continued)   Operating Mode = On Line   Operating Mode = Automatic   Operating Mode = Automatic (Object Sense) Exposure Modes Continuous Strobed Quick Reference Guide...
  • Page 16: Technical Features

    Technical Features Technical Features Item Description Physical Characteristics Color Grey Height 1.54" / 39mm Dimensions Length 2.24" / 57mm Width 2.28" / 58 mm Weight (without cable USB model - Approx. 5.0 ounces/140 g and brackets) RS-232 model - approx. 6.0 ounces/170 g Electrical Characteristics Input Voltage 5 VDC ±...
  • Page 17 Technical Features Item Description 5 mil - 2" to 6.3" (5cm to 16cm) 8 mil - 1.2" to 10.6" (3cm to 27cm) Depth of Field (Typical) 13 mil* - 1.2" to 15.7" (3cm to 40 cm) 20 mil - up to 23.6" (up to 60 cm) Minimum Element 3 mil Width...
  • Page 18: Rs-232 Electrical Connections

    Technical Features Item Description Contaminants IP54 ESD Level 16 KV Regulatory Led Emission Class (IEC-62471:2006-07) Exempt (No Risk) Electrical Safety IEC 60950-1 , CAN/CSA-C22.2 No. 60950-1-03; UL 60950-1 North America (FCC) : Part 15 Class B, Canada ( IC) : EMI/RFI ICES-003 Class B, European Union EMC Directive, Australian (C-tick), Russia (Gost)
  • Page 19 Technical Features Figure 3. Output Connection Vext 30Vdc max GFS4150-9 USER INTERFACE Figure 4. Using GFS4150-9 Power GFS4150-9 EXT TRIGGER TRIGGER Figure 5. Using External Power Supply GFS4150-9 EXT TRIGGER Vext 30Vdc TRIGGER Quick Reference Guide...
  • Page 20: Led And Beeper Indications

    LED and Beeper Indications LED and Beeper Indications Button and LED Status The top of the product has a button and three indicator LEDs: ON = Power ON POWER OFF = Power OFF or standby (only (yellow LED) USB model) ON = Good Read GOOD Blinks = USB enumeration or inter-...
  • Page 21: Ergonomic Recommendations

    Ergonomic Recommendations Ergonomic Recommendations In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury. CAUTION •...
  • Page 22: Regulatory Information

    Any changes or modifications to equipment, not expressly approved by Datalogic could void the user's authority to operate the equipment. Reader Labeling Labels are shown here to illustrate their location only. Please view the la- bels on your product for actual details.
  • Page 23 Webseite www.scanning.datalogic.com. Spanish Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico (WEEE), visite la página Web www.scanning.datalogic.com. Portuguese Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos (WEEE -Waste Electrical and Electronic Equipment), consultar o site web www.scanning.datalogic.com.
  • Page 24: Limitation Of Liability

    DOA (dead on arrival) defects. In order to obtain service under this Warranty, Customer must notify Datalogic of the claimed defect before the expiration of the Warranty period and obtain from Dat- alogic a return authorization number for return of the product to designated Datalogic service center. If Datalogic determines Customer’s claim is valid, Datalogic will repair or replace product without addi-...
  • Page 25: Risk Of Loss

    Datalogic's possession or product being returned to Customer by Datalogic, except such loss or damage as may be caused by the negligence of Customer, its agents or employees. In the absence of specific written instructions for the return of product to Customer, Data- logic will select the carrier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
  • Page 26 Reader Labeling NOTES Gryphon™ GFS4XXX...
  • Page 27 DECLARATION OF CONFORMITY EC-064 Rev.: 0 Pag.: 1 di 1 Datalogic Scanning Group Srl Via S. Vitalino, 13 Lippo di Calderara di Reno (BO) 40012 Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el...
  • Page 28 Telephone: 49 (0) 61 51/93 58-0 Telephone: (65) 6435-1311 germany.scanning@datalogic.com singapore.scanning@datalogic.com India Iberia Datalogic Scanning India Datalogic Scanning SAS Sucursal en España Telephone: 91- 22 - 64504739 Telephone: 34 91 746 28 60 india.scanning@datalogic.com spain.scanning@datalogic.com Italy United Kingdom Datalogic Scanning SpA Datalogic Scanning LTD Telephone: [39] (0) 39/62903.1...

Table of Contents