Maytag MAH2400AW Service Manual page 14

Compact washer
Hide thumbs Also See for MAH2400AW:
Table of Contents

Advertisement

Troubleshooting Procedures
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.
Motor windings
6
5
3
2
CN1
(CN1) Unplug connector and test Resistance at plug.
Rotor Orange Pin 1 to Gray Pin 3 = approx 2.5 ohms);
Stator Yellow Pin 5 to Violet Pin 4 = approx 1 ohms),
Stator Yellow Pin 5 to Blue Pin 6 = approx 1 ohms)
Dispenser Circuit
14
!
WARNING
4
1
Non ATC Cold Wash and Rinse = tap temperature
Non ATC Hot Wash = tap temperature
ATC Cold Wash = 65 Degrees +/- 10
ATC Warm Wash = 105 Degrees +/- 10
ATC Warm Rinse = 80 Degrees +/- 10 for final
rinse only, all others are tap cold
16023430 Rev. 0
Water temperatures
1
2 3 4 5
6 7 8 9
10
©2004 Maytag Services