Miele DA 3460 Operating And Installation Instructions page 21

Table of Contents

Advertisement

1) In extraction mode: when measuring
for the height of the wall housing unit
and the cut-out, account must be taken
of any accessories fitted, e.g. silencer,
DSM module.
2) Recirculation is possible with
conversion kit DUU 151.
3) DSM 400 is available as an optional
accessory.
* Installation is also possible in a
600 mm wide wall unit.
Appliance dimensions
Safety distances between cooktop
and rangehood (S)
The minimum safety distances
between the top of a cooktop and
the bottom of the rangehood are
as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
Cooking appliance
Electric cooktop
Open electric grill
Deep fat fryer (electric)
Multi-burner gas cooktop
with maximum 45.4 MJ/h
total output, with no burner
having a greater output
than 16.2 MJ/h.
Multi-burner gas cooktop
with total output greater
than 45.4 MJ/h, or a gas
cooktop including a single
burner with an output
greater than 16.2 MJ/h.
Single gas cooktop with a
maximum output of
21.6 MJ/h
Single gas cooktop with a
maximum output greater
than 21.6 MJ/h
See "Warning and Safety"
instructions for further information.
Distance
S
600 mm
650 mm
650 mm
650 mm
760 mm
650 mm
760 mm
21