9.5.10 M2 (2 Pin-Contact)

Top 330ºC - Bottom 100ºC
OK Industries 151/min
Pace
6/7

9.5.11 J753 (Microphone Socket)

Top 330ºC - Bottom 100ºC
OK Industries 151/min
Pace
6/7

9.5.12 SW-all (Key/Switch)

Top 330ºC - Bottom 100ºC
OK Industries 151/min
Pace
6/7
NOTE: Use Flux Pen Indium-Indalloy NC771 ONLY (Motorola P/N 1185768C01). Use flux
sparingly.
NOTE: Always protect switches from heat and Flux intrusion to avoid component malfunction.
NOTE: Keep alcohol or solvent away from switch area after rework to avoid reliability issues.Tack
down a couple of leads if necessary.
68P80401P05
MECHANICAL PARTS REWORK AND REPAIR: Mechanical Parts Rework Procedure
N-Q07
"J" over J753 during Removal Procedure.
"J" over J753 & "F" over M2 during Installation
Procedure.
N-P20
"F" over M2 during Removal Procedure.
"F" over M2 & "C" over J753 during Installation
Procedure.
N-Q07
"I" over nearby SW during Removal Procedure.
"I" over nearby SW & "I" over replaced SW during
Installation Procedure.