Display During Menu Operation; Operation Procedure Of Diag Menu And Sub-Menu; Diag Menu Selection; Sub-Menu Selection - Yamaha RX-V1200 Service Manual

Hide thumbs Also See for RX-V1200:
Table of Contents

Advertisement

When there is a history of
protection function due to
Version
abnormal voltage in the
(1 alphabet)
power supply section
Voltage display in %
When there is a history of
Version
protection function due to
(1 alphabet)
abnormal DC output
Voltage display in %
When there is a history of
protection function due to
Version
excessive heat sink
(1 alphabet)
temperature
Voltage display in %
* Additional causes of protection can be due to loose connections, associated components, CPU, etc.
* For the protection voltage value, refer to DIAG menu No.10 described later.
• History of protection function
When the protection function has worked, its history is stored in memory with a backup. Even if no abnormality is noted
while servicing the unit, an abnormality which has occurred previously can be defined as long as the backup data has
been stored.
The history of the protection function is cleared when DIAG is cancelled by selecting PRESET RESERVED (Memory
initialized) of DIAG menu No.10 or when the backup data is erased.

• Display during menu operation

During the DIAG operation, the menu list described in the section of the startup screen appears on the superimposed screen
and the function at work is indicated on the FL indicator. The contents displayed during the function operation are described
in the later section on details of functions.

• Operation procedure of DIAG menu and SUB-MENU

There are 18 MENU items, each of which has some SUB-MENU items.

DIAG menu selection

Main unit: Select the menu using
TUNING located in the sealing panel.
Remote control unit: Select the menu using

SUB-MENU selection

Main unit: Select the sub-menu using
located in the sealing panel.
Remote control unit: Select the sub-menu using
Cause: The voltage in the power supply section is abnormal.
Supplementary information: The abnormal voltage is displayed in % based on
5V as 100%.
Turning on the power without correcting the abnormality will cause the protection
function to work 1 second later and the power supply will be shut off.
Cause: DC output of the power amplifier is abnormal.
Supplementary information: The abnormal voltage is displayed in % based on
5V as 100%.
Turning on the power without correcting the abnormality will cause the protection
function to work 3 seconds later and the power supply will be shut off.
Cause: The temperature of the heat sink is excessive.
Supplementary information: The abnormal voltage is displayed in % based on
5V as 500%.
Turning on the power without correcting the abnormality will cause the protection
function to work 1 second later and the power supply will be shut off.
(Forward) and
(Reverse) keys of PRESET/
(Forward) and
(Reverse) keys.
(Forward) and
(Reverse) keys of PROGRAM
(Forward) and
(Reverse) keys.
RX-V1200/RX-V1200RDS/HTR-5490/RX-V2200
PRESET/
TUNING
DIAG menu selection
PROGRAM
SUB-MENU selection
Use these keys for
DIAG menu selection.
Use these keys for
SUB-MENU selection.
18