L52DF*ST Indoor Gas Fireplace

Section 4: Wiring

OPTIONAL
BATTERY
PACK
1.5V AA type
1.5V AA type
1.5V AA type
1.5V AA type
Installing the remote On/Off Wall Switch
The L52DFST* gas valve may be connected to a wall switch. Do
NOT connect any external power to the remote switch. The valve
will generate its own power on a millivolt circuit or will draw its
power from an AC Connection inside the fireplace, depending on
the model of the unit. Use only low voltage wire, and DO NOT
connect any external power to the remote switch.
Refer to Figure 12 or 13 for wiring requirements.
Page 16
Installation
SPARK
RED
BLACK
SENSOR
TO ON/OFF
BLUE
RED
WALL SWITCH
BLUE
WHITE
OPTIONAL CPI/IPI SWITCH
jumper
YELLOW/GREEN
ORANGE
GREEN
LED Lights
LED1 - Red LED
LED2 Amber LED
Figure 12. Wiring Diagram for the SIT Proflame 2 Electronic Ignition
'Hi-Lo' Adjustment Knob
Manifold Pressure
Test Connection
Inlet Pressure
Gas Control Knob (Shown in "Pilot" position)
Figure 13. Wiring Diagram for SIT Nova 820 gas and pilot.
X2
X1
X3
X4
6
X5
10
4
X10
6
X11
3
4
X12
X13
SW1
Pilot Adjustment Screw
NOTE: The switch location must not exceed 30' from the fire-
place.
NOTE: If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
Models Included
L52DF-STN-F
L52DF-STL-F
GREEN
WHITE
BLACK
To PPO
Models Included
Power
Generator
L52DF-STN
L52DF-STL
Wall Switch
XG0811 - 151126