6. Reposition agitator by sliding square
and round projections on agitator ends
into square and round slots ori sides of
nozzle. Roll agitator toward rear of
cleaner.
7. Reposition bottom plate. Replace
bottom plate screws. Tighten screws with
screwdriver.
8. To make sure agitator rotates, plug
cleaner into electrical outlet and turn
cleaner on.
If agitator does not rotate, the V-belt is not
positioned properly in the groove of the
idler pulley. Should this occur, proceed
as follows:
1.
Disconnect cleaner from electrical
outlet.
2. Referring to section "How to replace
belts", remove hood and reposition V-belt
into groove of idler pulley.
3. Reposition hood, turn cleaner over and
replace hood screws. Tighten screws
with screwdriver.
Power cord
To reduce twisting of the power cord, start
at the cleaner handle end of the cord and
coil before storing on storage hook.
If you have a problem
If a minor problem occurs, it usually can be solved quite easily when the cause is found by
using the check list below.
Problem
Cleaner
won't
run
Possible cause
Possible solution
1. Not firmly plugged in.
1. Plug cord in firmly.
2. No voltage in wall plug.
2. Check fuse or breaker.
3. Blown fuseitripped
3. Replace fuse/reset
breaker.
breaker.
Cleaner
won't
pick up
1.
2.
3.
4.
5.
6.
Broken or worn belt(s).
Agitator brushes worn.
Bag full/dirt cup full.
Incorrect carpet height
setting.
Agitator not rotating.
Heavy object clean out
full of debris.
1.
2.
3.
4.
5.
6.
Replace belt(s).
Replace agitator roll sleeve.
Empty bag/dirt cup; change
throw away bag.
Move nozzle control
knob to type of carpet
being cleaned.
Check V-belt positioning
in groove of agitator and of
idler pulley.
Empty heavy object clean
Out.
Cleaner
1. Incorrect carpet height
1. Move nozzle control
hard
setting.
knob to a higher setting.
to push
2. Agitator brushes worn.
2. Replace agitator roll sleeve.
Service
To obtain
approved
HOOVER service and genuine HOOVER parts,
locate the nearest
Hoover
Factory
Service
Center
or Authorized
Hoover
Commercial
Warranty
Service
Distributor
by:
.
checking the Yellow Pages under "Vacuum Cleaners -
Commercial & Industrial" OR -
.
checking the list of Factory Service Centers provided with
this cleaner OR -
.
calling
l-800-944-9200
for an automated
referral
of autho-
rized service
outlet locations
(U.S. only)
Do not send your cleaner
to The Hoover
Company
in North Canton
for
service,
this will only result in delay.
If further
assistance
is needed,
contact The Hoover Company Con-
sumer Response
Center,
North Canton,
Ohio 44720
Phone:
216-499-9499.
In Canada,
contact Hoover Canada, Burlington, Ontario L7R 4A8,
Phone: l-800-263-6376.
Always identify your cleaner by the
complete
model number when
requesting information or ordering parts. (The model number appears
on the bottom of the cleaner.)
. Lubrication
The motor and agitator are equipped
with sealed ball bearings.
The addition of
lubricant could cause damage.
Therefore,
do not add lubricant
to the motor
or agitator
bearings.