56 | Menu settings INSTALLER SETTINGS (contractors only)
8.8

Viewing system information

Installer settings: System info
For menu structure
To show various items of system information:
Installation date (automatically activated
during commissioning)
Boiler part number (fixed value from the
heating appliance)
Boiler date of manufacture (fixed value from
the heating appliance)
Controller part number and model (fixed
factory-set value)
Controller date of manufacture (fixed
factory-set value)
Controller software version (fixed factory-set
value)
6 720 645 349 (2010/09)
page 46.
8.9

Screed drying function

Installer settings: Floor drying
For menu structure and setting range
NOTICE: Screed destruction!
B Connect any non-mixed heating
circuit directly to the heating
appliance. For this, the heat
drawn via the screed to be dried
must be greater than the
minimum output of the heating
appliance.
B Program screed drying function
in accordance with screed
manufacturer's instructions.
B In spite of the screed drying
function, visit the system daily
and make the prescribed
reports.
The screed drying function allows fresh screed on
underfloor heating to be dried in accordance with
the screed manufacturer's instructions.
DHW heating is not possible from
programming to completing the
screed drying function.
Menu: Floor drying > Cancel floor drying
B This function can be switched off with Yes if
the screed drying function is activated.
Menu: Floor drying > Maximum CH flow
temperature
B Enter the maximum flow temperature (1) for
the screed drying function.
Menu: Floor drying > Maintain max CH flow
temp for
B Set period (2) for the maximum flow
temperature.