Adjustment
11
Needle rise, hook clearance, needle height (final adjustm.) and needle guard
.04.10
(On the PFAFF 1526 carry out this adjustment on both hooks)
● Set stitch length "4" and loosen screws 1, 2, 3 and 4.
● Set needle bar at 2 mm past b.d.c. and set hook point at "needle centre."
● Set hook clearance according to Requirement 1 and tighten screws 1.
● Loosen screws 5 and turn shaft 6 so that the shafts in the coupling do not touch each
● Tighten screws 2 and 5.
● Making sure there is a slight play in the gear, move the collar up and tighten screws 3.
11 - 12
Requirement
At stitch-length setting "4" and needle bar at 2 mm b.d.c.:
1. the hook point must be at "needle centre" with a hook-to-needle clearance of
0.05 to 0.1 mm;
2. the top of the needle eye must be 0.8 mm below the hook point;
3. and needle guard 9 must touch the needle just lightly.
4
2
3
6
9
7
8
0.05 - 0.1 mm
Fig. 11 - 10
other.
1
5
1
58.019