Whirlpool ADG 7340 Service Manual page 3

Table of Contents

Advertisement

S E R V I C E
Technical data
Flow rates/ Inlet volume
Flow meter (at 0.3 bar = quantity 1.1 l/min)
Spray pump
Drain pump
Pump height max.
Inlet valve
Spray arm lower
Sprayarm upper
Sprayarm/ Shower top
Electrical base data
Voltage
Frequency
Total power
Fuse
Spray pump motor permanent spray system
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Power consumption
Resistance
Heating - 1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat
self reset
(Temperature of water)
Fuse
Water safty options
Waterstop system
Single electric water inlet valve
Voltage
Frequency
Resistance
Whirlpool Europe
Customer Service
208
lmp/l
65
l/min
16
l/min
1.1
m
4
l/min
~ 33
l/min
~ 27
l/min
~ 8
l/min
220/ 230 V
50
Hz
2.0 - 2.2
kW
10
A
220/ 240 V
140
W
69
48
µ F
4
220/ 240 V
30
W
146
220/ 230 V
1.87/ 2.04 kW
24.5
~ 2.0
˚C/min
~ 115
˚C
~ 85
˚C
206
˚C
Electronic aqua control
220/ 240 V
50/ 60
Hz
3.76
kΩ
ADG 7340
8542 340 01840
Regenerating valve
Voltage
Frequency
Resistance
Coil of dispenser
Voltage
Frequency
Resistance
Reed contacts
flow meter
NTC
20 ˚C
25 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
Regeneration
Volume
after wash cycles
water hardness
Salt consumption
for regeneration
Number of cycles
with 2 kg salt
26.04.2004 / Page 3
Doc. No: 4812 718 19826
220/ 240 V
50/ 60
Hz
3.13
kΩ
220/ 240 V
50/ 60
Hz
1.3
kΩ
58.1
kΩ
47 .1
kΩ
38.2
kΩ
25.4
kΩ
17 .2
kΩ
11.8
kΩ
8.3
kΩ
6
kΩ
4
kΩ
3
300
cm
depending on the water
softener setting
0 - 40
˚dh
0 - 10.7
mmol/l
0 - 107
˚Fh
~ 77
g
~ 26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents