COMPONENTS AND MEASURED VALUES:
Indicated resistance values apply at room temperature
Values within ± 10% are regarded as normal.
Radio interference suppression filter
Heating element 1400W 120V
Heating element 1200W 120V
Thermistor
Combined dispenser 120V
Circulation pump 120V
Drain pump 120V
Spray arm divider 120V 60 Hz
Inlet valve single include flow sensor 120V
Inlet valve safety include flow sensor 120V
Halogen lamp =5 W/12V
Wax motor
Fan motor 120V
680K ohm
12 ohm
10 ohm
25K ohm
0.3K ohm
22 ohm
25 ohm
2.6K ohm
0.95K ohm
0.5K ohm
<10K ohm
1.1K ohm
0.18K ohm