F No. Standard Data Input; Mechanical Shutter Adjustment - Sony DSC-P30 Service Manual

Table of Contents

Advertisement

6. F No. Standard Data Input

Compensate the unevenness of the iris meter sensitivity.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Refer to "Picture Frame Setting" for YH and YL.
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
7
6
93
YH
8
6
01
79
9
6
07
10
6
01
00
11
6
01
BB
12
6
02
Note 3: The adjustment data will be automatically input to page:
F, address: 29 to 2D.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
6
2C
00
3
6
92
00
4
6
93
00
5
6
0
01
00
CAMERA
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
F
29 to 2D
Procedure
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
(Note 2)
(Note 2)
Press PAUSE button.
Check the data changes to "01".
Press PAUSE button.
Press PAUSE button. (Note 3)
Check the data changes to "01".
Procedure
Press PAUSE button.
Release the data setting
performed at step 2. (Refer to
page 5-14)

7. Mechanical Shutter Adjustment

Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Refer to "Picture Frame Setting" for YH and YL.
Adjusting method:
Order Page Address Data
1
0
01
2
3
6
2C
4
6
90
5
6
91
6
6
92
7
6
93
8
6
01
9
6
07
10
6
01
11
6
01
12
6
02
13
6
AB
Note 3: The adjustment data will be automatically input to page:
F, address: 5A, 6C to 7F and D4 to D8.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
2C
3
6
92
4
6
93
5
6
0
01
5-20
CAMERA
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
F
5A, 6C to 7F, D4 to D8
Procedure
01
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
01
00
00
YL
(Note 2)
YH
(Note 2)
79
Press PAUSE button.
Check the data changes to "01".
00
Press PAUSE button.
AD
Press PAUSE button. (Note 3)
Check the data changes to "01".
Check the data changes to "00".
Procedure
00
Press PAUSE button.
00
00
00
Release the data setting
performed at step 2 . (Refer
to page 5-14)
00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsc-p50

Table of Contents