3.
Locating the Faulty Point
3-1. Laser Power Check
1) Select the menu as follows. Control → Macro, and select
LDPtestL_S.ttl.
Press "Open". (Fig. 3-1, 3-2)
2) Press the "RESET" button (SW101) of the jig as prompted by the display.
3) Place probe of a laser power meter in the specified position
following the display as shown in Fig. 3-3. (See Fig. 3-3-a)
sensor probe
CDM65-RBD1
4 Fig. 3-3-a
Note : Do not add stress to an optical pick-up.
28
jig
optical pick-up
4 Fig. 3-1
4 Fig. 3-2
4 Fig. 3-3