Download Print this page

Moen MT302E Installation Instructions

Two handle tub & shower valve

Advertisement

Quick Links

Measurements
These are shown on the drawings. The
depth measurment is critical. The center
line of the supply and discharge piping
should be a maximum of 3-1/16" (78mm)
and a minimum of 2" (51mm) behind the
finished wall surface, including tile. This is
1-1/16" (27mm) of adjustment.
Pipe, ells and nipples are not furnished
with the valve.
CAUTION:
Before turning water on during either rough-in or trim-out, make sure that cartridge retainer nuts are in place. The cartridges and
retainer nuts were probably installed and tested before leaving the factory. Although it is unlikely, it is nevertheless possible that
through the handling of the valve by any number of persons the retainer nuts may not be properly installed. This should be care-
fully checked at time of rough-in and trim-out. If the retainer nuts are not properly installed, water pressure could force the
cartridges out of the casting. Personal injury or water damage to the premises could result.
TWO HANDLE
TUB & SHOWER VALVE
SPOUT
Always turn water off before disassembling the valve. Open both valve handles to
relieve water pressure and to insure that COMPLETE water shut-off has been accomplished.

INSTALLATION INSTRUCTIONS

THESE INSTRUCTIONS MUST BE
LEFT WITH HOMEOWNER
MT302E
MODEL 72964 Series

Advertisement

loading

Summary of Contents for Moen MT302E

  • Page 1: Installation Instructions

    If the retainer nuts are not properly installed, water pressure could force the cartridges out of the casting. Personal injury or water damage to the premises could result. INSTALLATION INSTRUCTIONS TWO HANDLE TUB & SHOWER VALVE SPOUT MT302E MODEL 72964 Series THESE INSTRUCTIONS MUST BE LEFT WITH HOMEOWNER...
  • Page 2 2. Turn on both hot and cold water supply valves and allow the water to run from tub spout for 15 seconds. 3. Pull up on the diverter knob on the tub spout and run water through the shower riser for 15 seconds. 4. Turn off the hot and cold cartridges, install the showerhead and check the system for leaks. MT302E...
  • Page 3 Disassembly CAUTION: Turn OFF BOTH water supplies and open BOTH faucet handles to relieve water pressure and insure that COMPLETE water shut-off has been accomplished. FOR WALL TUBE MODELS: Pry off handle knob insert, if necessary. Remove handle screw, knob or tri-blade handle, escutcheon, escutcheon retainer and then unscrew wall tube.
  • Page 4 Be sure to visit our website at www.moen.com When ordering parts, specify finishes. ©2007 Moen Incorporated • 25300 Al Moen Drive • North Olmsted, OH 44070-8022 U.S.A. In Canada Moen Inc. • 2816 Bristol Circle • Oakville, Ontario L6H 5S7 Printed in U.S.A.

This manual is also suitable for:

72964 series