Program Zones - Honeywell Lynx Touch L5200 Programming Manual

All-in-one home and business control system and alarm control panel
Hide thumbs Also See for Lynx Touch L5200:
Table of Contents

Advertisement

Screen Display
IP Fault Time (min)
00
Use DHCP
Yes
NIC IP Address
255.255.255.255
Subnet Mask
255.255.255.255
Gateway IP Address
255.255.255.255
DNS Server IP Address
255.255.255.255
GSM Rollover
No
GSM 24 Hour Test
No

Program Zones

Zones
5000-100-133-V0
Serial Number
Function & Programming Options
IP Fault Time (min) (displayed if IP is selected as Communications Path)
Enter 2-digits
00-99
Use DHCP
Yes
No
Note: If disabled the following options will be active.
NIC IP Address (Appears only if "no" was selected in the "Use DHCP Field")
Enter 4 part address
Subnet Mask (Appears only if "no" was selected in the "Use DHCP Field")
Enter 4 part address
Gateway IP Address (Appears only if "no" was selected in the "Use DHCP Field")
Enter 4 part address
DNS Server Address (Appears only if "no" was selected in the "Use DHCP Field")
Enter 4 part address
GSM Rollover (Appears only if "WiFi and GSM" was selected in the "Communications Path"
field)
Yes
No
GSM 24 Hour Test (Appears only if "WiFi and GSM" was selected in the "Communications
Path" field)
Yes
No
Zones
Select from the following zone options:
1. New
3. Back Door
5. Motion Sensor
7. – 44. New
45. – 47. New (Main)* Garage
48. – 64. New
140. – 147. 4 Button
148. – 155. New (Button Zones)
180. – 185. Temperature
180. – 187. Temperature
95. Fire
96. Medical
99. Police
Select a zone and then select "Edit" or "Add New" to program the next available zone.
Program the following options:(dependent upon Zone Type):
Serial Number
Zone Description 1
Device Type
Report
Serial Number
When "Serial Number" has been selected "Enter Serial Number or Activate" is displayed. The
transmitter serial number and loop number can be enrolled via RF transmission OR
manually.
Enroll via RF Learning To enroll the device using RF Learning mode three transmissions
(open/close) of the device will be required. The initial transmission activates the RF Learning
mode and the system will emit a single beep. A second transmission enrolls the serial
number and the system beeps two times and displays "Activate Sensor Again To Confirm". A
2. Front Door
4.Window
6.New
Zones 45 to 47 are reserved for Garage Door Zones (L5200)
Zones 45 to 48 are reserved for Garage Door Zones (L7000)
Z-Wave Thermostat zones (L5200)
Z-Wave Thermostat zones (L7000)
Loop Number
Zone Description 2
Response Type
Chime
Supervision
- 7 -